![Whitmore LUBRICURVE ELECTRO 15 Installation & Maintenance Manual Download Page 18](http://html1.mh-extra.com/html/whitmore/lubricurve-electro-15/lubricurve-electro-15_installation-and-maintenance-manual_977317018.webp)
18
The first wheel of the train initiates the pump. The control panel counts the set number of wheels and
then operates the pump grease / friction modifier is then dispensed every time the set number of wheels
has been detected.
The volume output is set in two ways depending on the application:
Running Rail
Set the desired pump run time (time control systems) in seconds or desired pump steps (step
control systems)
Top of Rail
Set the desired pump steps, typically this would be between 2 and 4 steps.
Both types of control panel look very similar and the method of setting the pump step and pump run
time / steps is similar.
11.3.1
Backlight & voltage display feature panel - Running Rail
•
In order to access the control panel, open the main door of the cabinet.
•
Ensure the control panel is switched on. The power button (1) must be pressed on the “I”
rather than the “O”. The controls are now sitting in a neutral state with the battery power
allowing basic function.
•
The Electro 15 lubricators are activated by the Wheel Sensor ‘seeing’ the first wheels of a
train (step control option). When this occurs the Wheel Detected lamp (9) will illuminate as
the sensor registers a passing wheel. This situation can be replicated by passing a steel object
over the sensor. On time based systems the operation is not triggered by the first wheel but
on each wheel at the interval set irrespective of trains.
Battery
Back Light
ON
OFF
Volts
QHi
Rail
UK 01525 461123
www.qhigroup.com
Serial Number
Wheel
Detected
ON
Pump
Inhibited
Pump
Less
More
Wheels
Steps
Wheel Count
Pump Steps
Wheel Count
Total
Total
Pump Steps
Run
Stop
Run
Pump
10 Sec MAX
Battery
Motor
Wheel Sense
Motor Sense
D
ri
v
e
+ -
+ -
- s + - s +
UK 01582 622202
www.Whitmore
Railrail.com