COMPONENT DEFINITIONS
PAGE 37
AIR WASH
To inhibit buildup of soot on the door glass, air is deliv-
ered to the glass through an air wash system located in
the doorframe surrounding the glass.
AUGER
It transfers the fuel down the burner tube into the burn
grate.
AUGER MOTOR
Drives the Auger. Motor specifications are: .4 Amp, 1
rpm (revolutions per minute).
BLOWER, ROOM AIR (CONVECTION)
The blower function is to transfer the heat from the ap-
pliance to heat the room air.
BLOWER, EXHAUST (DRAFT INDUCER/COMBUSTION)
It has a radial impeller to deliver more air to the burn
grate. It pulls air into the burn grate by creating a nega-
tive pressure. This is done by extracting the exhaust
gases out of the firebox and pushing the exhaust down-
stream to the flue exit.
DISC, HIGH LIMIT (L250-30F, N / C)
There are 2 of these discs on this model. If a tempera-
ture reaches 250
°
F., the high limit auto reset will “trip”
and stop the flow of electricity to the auger motor. The
discs will not automatically reset until it has cooled be-
low 220
°
F).
Disc for Room Air Blower
– This disc is located
on the Room Air Blower jacket and is designed to
detect an overfire condition.
Disc for Combustion Air Inlet
– This disc is lo-
cated on the combustion air inlet and is designed
to detect reversed flow. If negative pressure in the
dwelling (i.e. An extremely tight house which may
not supply adequate combustion and ventilation
air) causes the exhaust to pull back from the com-
bustion air inlet, the heat from the exhaust will re-
sult in heat activation of this disc.
HOPPER
The hopper is where the pellets are stored.
HEAT OUTPUT BUTTON
This is the main power button, which controls power to
the feed system auger motor and exhaust blower. It has
3 feed rate settings, which controls the burn rate.
PHOTOEYE
The photoelectric eye that senses the flame, or lack of.
It is designed to signal the control board to discontinue
power to the auger motor if it flame is not sensed in the
UltraGrate
.
PRESSURE SWITCH
A safety device used to shut off the feed system (auger
motor) if there is too much back pressure in venting
system. Some possible causes are as follows:
♦
The venting system is obstructed.
♦
High altitude or other misc. environmental condi-
tions affecting exhaust flow.
♦
Improper venting system.
ULTRAGRATE
(BURN GRATE)
This is where combustion occurs and may be referred
to as the "burn grate".
Summary of Contents for Advantage Optima 2 FS
Page 38: ...WIRING DIAGRAM PAGE 38 ...
Page 44: ...REPLACEMENT PARTS DIAGRAMS PAGE 44 5 6 8 10 13 14 9 12 7 11 ...
Page 45: ...REPLACEMENT PARTS DIAGRAMS PAGE 45 15 16 17 19 20 22 24 25 26 27 18 23 ...
Page 46: ...REPLACEMENT PARTS DIAGRAMS PAGE 46 30 37 38 40 41 29 28 33 34 39 31 32 35 ...
Page 47: ...REPLACEMENT PARTS DIAGRAMS PAGE 47 43 44 45 46 47 42 ...
Page 49: ...INSTALLATION TIPS PAGE 49 ...