Please note: All images shown are for illustration purposes and should be used only for reference.
General Description
Florin E3 is a range of stand-alone IP65 LED
emergency luminaires incorporating a driver and
battery pack in a plastic housing. The luminaire
contains a high-power white LED and indicator LED
for emergency use only.
The LED control gear has reinforced insulation
between the supply and the battery circuit, and a
battery charger with short circuit protection that will
continue to operate when the short is removed.
Batteries (where applicable)
The luminaire includes a 1.5Ah rechargeable
LiFePO
4
battery pack for 3 hour operation. When
the luminaire no longer meets the 3 hours duration
the battery should be replaced.
Relevant Standards
EN 61347-2-7 Lamp control gear
EN 61347-2-13 LED control gear
EN 60598-2-22 Luminaire
IMPORTANT:
Please ensure that the information contained in this
leaflet is passed on to the user/maintenance engineer.
Mark the luminaire with the date of commissioning in
the space provided on the battery label.
The battery lead should only be connected at the time
of commissioning.
When the supplies and battery leads are connected,
the white cover should be
‘clicked’ into place to
prevent electric shock.
The LED is non-replaceable. Contact Whitecroft
Lighting in the unlikely event of a failure.
Operation
– integrated battery versions
Upon connection of a permanent mains supply the
indicator LED lights to show the battery is receiving
charge. Following an initial charging period,
commissioning test and a subsequent charging period
of 24 hours the unit will be capable of providing 3
hours emergency duration.
Operation
– central battery
When power is supplied to the luminaire supply inputs,
the high-power LED will light.
Installation
The luminaire must be installed by a qualified person
in accordance with the current building and wiring
regulations. Luminaires comply with the EMC directive
in both modes of operation, mains and emergency.
The luminaire is designed to be surface mounted onto
a ceiling.
Automatic Commissioning
(FLS31EP/65, FLS32EP/65 & FLSH31EP/65 only)
Please note there is no need to do a manual test on
this product.
If in the unlikely event a manual test needs to be
undertaken please ensure it has completed the
commissioning phase as per the table below.
Do not connect the batteries until there is a
reliable
permanent mains supply present as a mains
interruption will rest the commissioning test clock.
The commissioning test will start when the permanent
supply and batteries are connected.
Commissioning phase table
Stage
Hours
Status
LED
Indication
1
upto
24
Battery
charging
Flashing
green
2
3
Discharge test
Flashing
green
3
24
Battery
charging
Flashing
green
4
0
Commissioning
complete
Constant
green
Total
51