background image

10

SER

SER

SER

SER

SERVICE INDICA

VICE INDICA

VICE INDICA

VICE INDICA

VICE INDICATION

TION

TION

TION

TION

SER

SER

SER

SER

SERVICE CHECKS

VICE CHECKS

VICE CHECKS

VICE CHECKS

VICE CHECKS

ON/OFF switch “ON”

Unit functioning Nor

Unit functioning Nor

Unit functioning Nor

Unit functioning Nor

Unit functioning Normall

mall

mall

mall

mally

y

y

y

y

Blower ON
Operating Light ON

ON/OFF switch “ON”

1.

1.

1.

1.

1.

P

P

P

P

Po

o

o

o

ow

w

w

w

wer is not being supplied to air c

er is not being supplied to air c

er is not being supplied to air c

er is not being supplied to air c

er is not being supplied to air cleaner

leaner

leaner

leaner

leaner.....

Blower ON

A. Check fuse or circuit breaker.

Operating Light OFF

B. Ensure power pack is properly installed and latched.

2.

2.

2.

2.

2.

Collecting cell shor

Collecting cell shor

Collecting cell shor

Collecting cell shor

Collecting cell shorted - 

ted - 

ted - 

ted - 

ted - T

T

T

T

Tur

ur

ur

ur

urn po

n po

n po

n po

n pow

w

w

w

wer Of

er Of

er Of

er Of

er Offffff  -  R

 -  R

 -  R

 -  R

 -  Remo

emo

emo

emo

emov

v

v

v

ve po

e po

e po

e po

e pow

w

w

w

wer pac

er pac

er pac

er pac

er pack - R

k - R

k - R

k - R

k - Remo

emo

emo

emo

emov

v

v

v

ve

e

e

e

e

 collecting cells - R

 collecting cells - R

 collecting cells - R

 collecting cells - R

 collecting cells - Re

e

e

e

eplace po

place po

place po

place po

place pow

w

w

w

wer pac

er pac

er pac

er pac

er pack - R

k - R

k - R

k - R

k - Restor

estor

estor

estor

estore po

e po

e po

e po

e pow

w

w

w

wer (ensur

er (ensur

er (ensur

er (ensur

er (ensure b

e b

e b

e b

e blo

lo

lo

lo

low

w

w

w

wer is

er is

er is

er is

er is

oper

oper

oper

oper

opera

a

a

a

ating).

ting).

ting).

ting).

ting).

A. If  Operating Light comes ON check cells for bent plates, loose ionizing

wire(s) or cracked insulator(s).

B. If  Operating Light remains OFF, malfunction is in the power pack. (See

power supply Checkout Procedure).

ON/OFF Switch “ON”

1.

1.

1.

1.

1. Air f

Air f

Air f

Air f

Air flo

lo

lo

lo

low sensor contamina

w sensor contamina

w sensor contamina

w sensor contamina

w sensor contaminated/misaligned

ted/misaligned

ted/misaligned

ted/misaligned

ted/misaligned

Blower OFF

A. Remove power pack and clear contamination inside black bushing around

Operating Light ON

the small sensor element.

B. Ensure small sensor element is centered in bushing.

2.

2.

2.

2.

2. Air sensor left in b

Air sensor left in b

Air sensor left in b

Air sensor left in b

Air sensor left in bypassed condition after ser

ypassed condition after ser

ypassed condition after ser

ypassed condition after ser

ypassed condition after servicing

vicing

vicing

vicing

vicing.**

.**

.**

.**

.**

3.

3.

3.

3.

3. F

F

F

F

Faulty air f

aulty air f

aulty air f

aulty air f

aulty air flo

lo

lo

lo

low sensor panel.

w sensor panel.

w sensor panel.

w sensor panel.

w sensor panel.

Excessive arcing during

1.

1.

1.

1.

1. W

W

W

W

Wet collecting cell.

et collecting cell.

et collecting cell.

et collecting cell.

et collecting cell.

normal operation -

A. Allow cell(s) to dry after cleaning before applying power.

Operating Light may blink

2.

2.

2.

2.

2. Dama

Dama

Dama

Dama

Damag

g

g

g

ged collecting cell(s).

ed collecting cell(s).

ed collecting cell(s).

ed collecting cell(s).

ed collecting cell(s).

A. Remove cell(s) and inspect for bent plates, loose ionizing wire(s), cracked

insulator(s), etc.

3.

3.

3.

3.

3. Collecting cells dir

Collecting cells dir

Collecting cells dir

Collecting cells dir

Collecting cells dirty

ty

ty

ty

ty.....

A. Clean cells as instructed in this manual.

4.

4.

4.

4.

4. F

F

F

F

Faulty po

aulty po

aulty po

aulty po

aulty pow

w

w

w

wer suppl

er suppl

er suppl

er suppl

er supply (see po

y (see po

y (see po

y (see po

y (see pow

w

w

w

wer suppl

er suppl

er suppl

er suppl

er supply c

y c

y c

y c

y chec

hec

hec

hec

heck

k

k

k

kout pr

out pr

out pr

out pr

out procedur

ocedur

ocedur

ocedur

ocedure)

e)

e)

e)

e)

**NO

**NO

**NO

**NO

**NOTE:

TE:

TE:

TE:

TE: Your air cleaner may be equipped with an air flow sensor (switch) which turns the unit ON and OFF in

response to the system blower. It may have been “wired out” during a service check and inadvertently left in this
condition.

B

B

B

B

BASIC SST SER

ASIC SST SER

ASIC SST SER

ASIC SST SER

ASIC SST SERVICE GUIDE

VICE GUIDE

VICE GUIDE

VICE GUIDE

VICE GUIDE

This guide will cover most homeowner complaints. If, after checking the items listed, the unit still fails to operate
properly, contact the nearest Authorized Service Center.

Summary of Contents for Comfort Plus SST1000

Page 1: ...rts Repair Parts Repair Parts Repair Parts Repair Parts PART NO 37 6373F PART NO 37 6373F PART NO 37 6373F PART NO 37 6373F PART NO 37 6373F Replaces 37 6373E 0631 Please read and familiarize yourself...

Page 2: ...Installation of this unit must comply with local electric Installation of this unit must comply with local electric Installation of this unit must comply with local electric Installation of this unit...

Page 3: ...ot be removed by an Electronic Air Cleaner or by any other filtration media designed to remove airborne particles However some gases can be absorbed by an activated carbon filter or diluted with fresh...

Page 4: ...5 If the air cleaner has a power cord installed unit must be located close enought to the outlet so connection can be made without the use of an extension cord If your furnace duct system has a pre i...

Page 5: ...ing If duct connection to furnace allows less than nine inches for mounting the air cleaner shorten the lateral trunk or attach an offset fitting to the elbow HORIZONTAL FURNACE HORIZONTAL FURNACE HOR...

Page 6: ...the furnace If necessary enlarge the opening in the furnace if possible to match the opening in the cabinet Ifthefurnaceopeningcannotbeenlarged atransition fitting should be used Figure 3 The cabinet...

Page 7: ...ectors prop erly installed and grommets used to prevent wire abrasion Vertical Section Wood Block Tape All Joints Figure 16 Hot Neutral Grounding Conductor Front View Figure 17 Cabinet Pre Filters Han...

Page 8: ...f the noise is objectionable push the ON OFF switch to the OFF position and allow additional time for cell s and pre filter s to dry In some cases the Operating Light will remain OFF during this initi...

Page 9: ...Make sure wire is securely anchored at each end Support Ionizing Wire Figure 21 Rated Capacity 600 1200 cfm 1000 1600 cfm 1000 2000 cfm 1600 2200 cfm Max Pressure Drop 08 in W G 08 in W G 12 in W G 0...

Page 10: ...misaligned ted misaligned Blower OFF A Remove power pack and clear contamination inside black bushing around Operating Light ON the small sensor element B Ensure small sensor element is centered in bu...

Page 11: ...rovider Failure to do so could result in reduced perfor Failure to do so could result in reduced perfor Failure to do so could result in reduced perfor Failure to do so could result in reduced perfor...

Page 12: ...th no cell attached 3 Place power pack on top of collecting cell ensuring that there is proper contact between the cell contact on the power pack contact 4 Using a standard extension cord apply 120 VA...

Page 13: ...cting cell 2 Insert the two collecting cells into the cabinet behind the pre filters Be sure ionizing wires are directly behind the pre filters so the particles can be charged as soon as the air leave...

Page 14: ...14 15 18 REP REP REP REP REPAIR P AIR P AIR P AIR P AIR PAR AR AR AR ARTS TS TS TS TS...

Page 15: ...2 F858 1002 F858 1002 F858 1002 15 Cover Power Pack F16 8520 F16 8520 F16 8521 F16 8521 16 Manual 37 6373 37 6373 37 6373 37 6373 17 Charcoal Filter with mounting clips F825 0466 F825 0467 F825 0468 F...

Page 16: ...lesaler or Original Equipment Manufac turer Sincerely White Rodgers Year JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC 20___ 20___ 20___ 20___ 20___ 20___ 20___ 20___ 20___ 20___ 20___ 20___ WASH RE...

Reviews: