background image

14015-1-0903

Page 9

PLACEMENT OF GLOWING EMBERS  AND LAVA ROCK

Placement of the glowing embers (rock wool) is very individual
and light coverage of the areas indicated will provide your best
effects. We recommend separation of the rock wool by hand and
make your coverage as light and fluffy as possible.

Place just enough embers on the burner to obtain the glow and a
gold, yellow flame.

Do not place embers (rock wool) over large ports in rear portion
of burner.

Rock wool should 

not

 be placed in the area of the pilot assembly.

Placing Lava Rock in Front of Burner on Fireplace Floor

Spread lava rocks on fireplace floor in front of the burner pan.
The lava rocks are for decorative effect and are not required for
fireplace operation.

ATTENTION:

 DO NOT PLACE LAVA ROCKS ON

BURNER, LOGS OR ROCK WOOL. THE LAVA ROCKS
SHOULD ONLY BE PLACED ON THE FIREPLACE
FLOOR.

Figure 5

Flames from the pilot (right back side of the pan burner) as well
as the main flame should be visually checked as the log set is
installed.

In normal operation at full rate after 10 to 15 minutes, the flame
appearance should be sets of yellow flames.

NOTE:

 all flames will be random by design, flame height will

go up and down.

Avoid any drafts that alter burner flame patterns. Do not allow
fans to blow directly into fireplace. Do not place a blower inside
the burner area of the firebox. Ceiling fans may create drafts that
alter flame patterns. Sooting and improper burning will result.

During manufacturing, fabricating and shipping, various
components of this appliance are treated with certain oils, films
or bonding agents. These chemicals are not harmful, but may
produce annoying smoke and smells as they are burned off during
the initial operation of the appliance, possibly causing headaches
or eye or lung irritation. This is a normal and temporary
occurrence.

The initial break-in operation should last 2-3 hours with the burner
at the highest setting. Provide maximum ventilation by opening
windows or doors to allow odors to dissipate. Any odors remaining
after this initial break-in will be slight and will disappear with
continued use.

OPERATION INSTRUCTIONS/FLAME APPEARANCE

Manual - Figure 6

Millivolt - Figure 7

Summary of Contents for VSM-18-1

Page 1: ...ncesinfuelorfromfuelcombustionwhich can cause death or serious illness The White Mountain Vented Slope Glaze Burner INSTALLATION INSTRUCTIONS AND OWNER S MANUAL Installer Please leave these instructions with the consumer Consumer Please retain these instructions for future use VENTED DECORATIVE LOG SET FOR INSTALLATION IN SOLID FUEL BURNING FIREPLACES MODELS VSM 18 1 VSR 18 1 VSM 24 1 VSR 24 1 VSM...

Page 2: ...e Characteristics 12 Wiring 13 Cleaning and Servicing 13 Troubleshooting 14 Parts List 15 Parts View 16 How to Order Repair Parts 16 Propane LP Gas Conversion Instructions 17 Natural Gas Conversion Instructions 18 Service Notes 19 TABLE OF CONTENTS CAUTION If logs or branches are damaged do not use A certain amount of sooting will occur which enhances the realistic look of the logs and branches If...

Page 3: ...raturesandshouldstayawaytoavoid burns or clothing ignition Young children should be carefully supervised when they are in the same room as the appliance Clothing or other flammable material should not be placed on or near the appliance Do not place trash or other articles on the log set during operation During manufacturing fabricating and shipping various components of this appliance are treated ...

Page 4: ...m service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas Odor fade due to oxidation by rust or adsorption on walls of new cylinders and tanks is possible Therefore people should be particularly alert and careful when new tanks or cylinders are placed in service Odor fade can occur in new tanks or reinstalled old tank...

Page 5: ...s Rock Wool 1 Damper Clamp 2 Bags Decorative Rock Always consult your local Building Department regarding regula tions codes or ordinances which apply to the installation of a vented decorative gas log set in a solid fuel burning fireplace This appliance is only for use with the type of gas indicated on the rating plate Instructions to Installer 1 Installer must leave instruction manual with owner...

Page 6: ...size identification For Canadian high altitude applications this appliance is suitable for installation at elevations between 0 feet 0m and 4 500 1 370m without change Wheninstallingthisunitatanelevationabove4500feet 1 370m in Canada check with local authorities Consult your local gas utility for assistance in determining the proper orifice for location FIREPLACE PREPARATION Turn off gas supply to...

Page 7: ...6 25 7 33 8 41 7 49 2 56 6 64 0 8 16 5 23 7 31 2 38 7 45 5 52 4 59 7 10 15 1 21 7 28 7 35 2 41 7 48 2 54 3 15 14 1 19 9 26 1 32 0 37 7 43 2 48 8 20 12 9 18 5 23 7 28 8 34 3 39 8 44 4 30 12 2 16 9 21 6 26 5 31 2 35 9 40 3 ApplianceInputRate KW HR 5 9 8 8 11 7 14 6 17 6 20 5 23 4 Chimney Height MinimumOpening cm2 m 1 83 113 6 165 8 218 1 269 0 317 4 365 2 412 9 2 44 106 5 152 9 201 3 249 7 293 6 338...

Page 8: ... 45 Assembled Flexible Appliance Connectors of Other Than All Metal Construction The above connectors may be used if acceptable by the authority having jurisdiction The state of Massachusetts requires that a flexible appliance connector cannot exceed three feet in length Figure 4 Pressure Testing of the Gas Supply System 1 To check the inlet pressure to the gas valve a 1 8 3 175mm N P T plugged ta...

Page 9: ... is installed In normal operation at full rate after 10 to 15 minutes the flame appearance should be sets of yellow flames NOTE all flames will be random by design flame height will go up and down Avoid any drafts that alter burner flame patterns Do not allow fans to blow directly into fireplace Do not place a blower inside the burner area of the firebox Ceiling fans may create drafts that alter f...

Page 10: ...e is in operation A fireplace screen must be in place when the appliance is operating and unless other provisions for combustion air are provided the screen shall have an opening s for introduction of combustion air VSM 18 24 30 LIGHTING INSTRUCTIONS 1 Push in gas control knob slightly and turn clockwise to OFF Do not force 1 STOP Read the safety information above 2 Push in manual gas con trol kno...

Page 11: ...shall be opened when the appliance is in operation A fireplace screen must be in place when the appliance is operating and unless other provisions for combustion air are provided the screen shall have an opening s for introduction of combustion air LIGHTING INSTRUCTIONS VSR 18 24 30 LIGHTING INSTRUCTIONS 1 STOP Read the safety informa tion above 2 SettheON OFFswitchto OFF 3 Turn off all electric p...

Page 12: ...ment Use a pipe cleaner to clean inside the pilot after the pilot orifice has been removed To Remove Pilot Orifice 1 Disconnect the pilot supply line at the pilot burner 2 Remove pilot orifice from pilot burner It may be necessary to tap on pilot burner in order to remove the pilot orifice Pilot Flame Pattern Figure 9 If pilot flame pattern is incorrect See Troubleshooting page 15 Main Burner Flam...

Page 13: ... Receiver VSR 18 24 30 Use the following steps to place the remote receiver adjacent to the gas valve Attention 1 The remote receiver can not be placed behind the gas valve and burner assembly 2 When facing the appliance the remote receiver must be placed in the right side firebox toward the front Note Do not let remote control receiver come in contact with burner assembly Refer to remote control ...

Page 14: ...ermopile Check all connections and try If still not operating disconnect lead between thermo couple switch and valve operator Then disconnect lead to pilot magnet and connect to valve operator terminal TP TH If pilot remains lit fault lies with thermocouple Check that bulb is in proper location If still not working replace thermocouple see drawing in manual for additional information 3 Pilot burni...

Page 15: ...CH LOG ASSEMBLY NS R 5699 WIRE HARNESS NS R 5757 ON OFF SWITCH NS 15432 TUBING VALVE TO PILOT NS 15430 TUBING VALVE TO BURNER NS 15496 ROCK WOOL NS 11788 DECORATIVE ROCK NS R 2809 DAMPER CLAMP NS R 734 LIGHTER ROD NS R 1054 THERMOPILE VSM 18 24 30 5 P 265 ORIFICE LPG 18 40 000 BTU 4 P 211 ORIFICE NAT 18 40 000 BTU 4 P 256 ORIFICE LPG 18 65 000 BTU 4 P 273 ORIFICE NAT 18 65 000 BTU 4 P 257 ORIFICE ...

Page 16: ...ne the Part Number not the Index Number and the Description of each part from the following appropriate illustration and list Be sure to give all this information Applaince Model Number Part Description Appliance Serial Number Part Number Type of Gas Propane or Natural Do not order bolts screws washers or nuts They are standard hardware items and can be purchased at any local hardware store Shipme...

Page 17: ...t orifice removed from the appliance for future use 9 Insert Propane LP gas pilot orifice marked 8 into pilot burner 10 Attach pilot tubing into pilot burner 11 Connect gas supply line to vented decorative log set 12 AttachR 1322 conversionlabelandR 1321 gasconversion label to the 4 3 4 x 7 1 4 metal plate supplied in conversion kit Attach 4 3 4 x 7 1 4 metal plate to metal chain which is attached...

Page 18: ...BTUH input For VSR 30 install one Natural gas main burner orifice marked 26 for 60 000 BTUH input 7 Remove pilot tubing from pilot burner 8 Remove Propane LP gas pilot orifice from pilot burner Save the Propane LP gas pilot orifice removed from the appliance for future use 9 Insert Natural gas pilot orifice marked 12 into pilot burner 10 Attach pilot tubing into pilot burner 11 Connect gas supply ...

Page 19: ...14015 1 0903 Page 19 SERVICE NOTES ...

Page 20: ...3 Empire Comfort Systems Inc Nine Eighteen Freeburg Ave Belleville Illinois 62220 2623 PH 1 618 233 7420 PH 1 800 851 3153 FAX 1 618 233 7097 FAX 1 800 443 8648 E MAIL info empirecomfort com WEB SITE www empirecomfort com ...