11.Connect the lineset piping according to the instructions on page 15
10. Using a 1/4” wrench or socket, tighten the accessible
mounting screws on the left-hand side of the interior of the
unit.
Note:
For ease of installation, remove the top panel after
securing unit to wall.
°
F
°
F
°
F
INSTALLING THE EVAPORATOR UNIT, CONTINUED
12. Route power supply wires into the unit through the power knockout and install the supplied strain relief.
13. Connect power supply wires to the wires located inside of the unit (hot=black, neutral=white, ground=green).
14. After the suction line has been insulated, connect the bottle probe. Secure loose bottle probe cable with cable ties.
Note:
Reinstall top panel if you removed it earlier.
15. Reinstall the access panel removed in Step 1 on page 10 by pushing the four corners into place.