Compressor runs, but evaporator does not
1. Faulty blower
motor or broken wire
connection
• Evaporator coil probably frozen
• Shut off power to condensing unit
• Call a CERTIFIED HVAC service technician for repair
2. Defective low
pressure switch not
shutting compressor off
when pressure drops
• Compressor would continue to run when thermostat is
satisfied and shuts blower and solenoid off. When space
warms up to set point, blower starts and the system
runs normally.
• Prolonged running without refrigerant flow will
damage or destroy compressor. If this condition exists,
call a CERTIFIED HVAC service technician.
Compressor short cycles, which is different from running intermittently
1. System pressure
controls defective.
Call a CERTIFIED HVAC service technician to verify and
repair.
2. System low on
refrigerant.
Observe for flashing in refrigerant sight glass located in 1/4”
copper tube at condensing unit. If flashing with bubbles,
call a CERTIFIED HVAC service technician for leak location,
repair, and adding refrigerant.
3. Condenser fan motor
defective
• Fan does not run with compressor.
• ¼” Copper tube at sight glass – very hot, compressor
very hot, runs short time, shuts off.
• Shut power off to condensing unit
• Call a CERTIFIED HVAC service technician for repair.
4. Compressor starting
components defective.
• Compressor very hot and hums when trying to start.
• Shut power off to condensing unit.
• Call a CERTIFIED HVAC service technician.
Evaporator coil freezes
1. Air filter, if equipped,
dirty
Clean or replace filter
2. Evaporator coil and/
or blower dirty
Clean coil and blower
3. Thermostat set point
too low.
Set point should not be lower than 50°. If so, increase to
above 50°
4. System low on
refrigerant
Check refrigerant “sight glass” in 1/4” tubing. Check for bubbles
after system has run for several minutes. If bubbles present,
call a CERTIFIED HVAC service technican. If sight is clear of
bubbles, refrigerant level is OK.
Summary of Contents for 81310
Page 25: ...Page 23 Platinum Split 4000 8000 Condenser Terminal Board ...
Page 26: ...Page 24 GSM 01 081310 Mini Split Evaporator Terminal Board ...
Page 27: ...Page 25 Mini Split Condenser Terminal Board ...
Page 33: ...NOTES ...
Page 34: ...WhisperKOOL 1738 E Alpine Ave Stockton CA 95205 1 800 343 9463 www whisperkool com ...