Page 17
TROUBLESHOOTING
Fault
Cause
Solution
Water leaking from unit
1. Condensate drain
clogged
Clear out drain
2. Evaporator coil
frozen
Clean the coil and / or fan wheel
3. Drain line improperly
installed
Call a CERTIFIED HVAC service technician.
Wine cellar temperature above thermostat set point
1. Large quantity of warm
wine placed in cellar
Allow time for wine to cool
2. Wine Cellar Door left
open for long period.
Close Door. Allow time for wine to cool.
3. No power to either
evaporator or condensing
unit
Is the thermostat display illuminated?
If not, check power supply switch, if equipped. Ensure it is in the
ON position.
If on, check to see in the breaker is tripped.
If tripped, reset and check display.
Check breaker to condensing unit. If tripped, check to see if com-
pressor is hot – too hot to touch. If so, allow to cool for one (1)
hour before resetting breaker.
After cooling, reset breaker and note whether it remains set or
trips off. If it trips, call a CERTIFIED HVAC service technician for
repair.
Display Alarm Codes
Message
Cause
Outputs
“P1”
Room probe failure
Compressor output acc. to par. “Con” and “COF”
“P2”
Evaporator probe failure
Defrost end is timed
“HA”
Max bottle probe temp alarm
Outputs unchanged
“LA”
Min bottle probe temp alarm
Outputs unchanged
“EA”
External alarm
Outputs unchanged
Summary of Contents for 81310
Page 25: ...Page 23 Platinum Split 4000 8000 Condenser Terminal Board ...
Page 26: ...Page 24 GSM 01 081310 Mini Split Evaporator Terminal Board ...
Page 27: ...Page 25 Mini Split Condenser Terminal Board ...
Page 33: ...NOTES ...
Page 34: ...WhisperKOOL 1738 E Alpine Ave Stockton CA 95205 1 800 343 9463 www whisperkool com ...