MAINTENANCE
W-GV4 Scalino outdoor — April 2017— EN
19
5.5
Putting out of service
When not using the Genverter for a longer period it is
recommended to execute an engine preservation procedure.
1
Clean the engine.
2
Loosen the fuel suction pipe and fuel return and put them
in a can with preservation diesel fuel. Start the engine and
run the engine warm.
3
Stop the engine.
4
Drain the hot engine oil and refill with preservation oil.
5
Open the orange oil screw plug on the cylinder cover and
add 2 cc preservation oil. Then rotate the engine.
6
Disconnect the battery and store it in a dry place free of
frost and charge it regularly.
7
Close inlet- and outlet openings with tape.
8
Protect the Genverter against the influences of bad weather
conditions.
This method of preservation will be sufficient for 6 months.
Change oil before using the engine again.