TROUBLE SHOOTING
32
December 2010 / M-SC6/8/10 / EN
PROBLEM CAUSE
SOLUTION
•
Wear out of cylinder.
Have the compression measured and have the
engine overhauled.
Over-temperature
•
Overload.
Take away the overload.
•
Low level of cooling oil or air in the
cooling system
Fill up with liquid and release air bubbles.
Check if there are air blocks in the system;
refer to the installation manual
•
Water inlet system blocked.
•
Broken impeller.
•
Water strainer choked
•
Heat exchanger choked.
Check the cooling system thoroughly.
•
Broken or slipping V-belt.
Replace and adjust the V-belt tension.
•
Faulty thermostat
Check the thermostat or replace.
5.2.3 Warnings
Generator must be shut off immediately if:
●
Motor RPM suddenly rises or drops.
●
Unusual noise comes from generating set.
●
Exhaust gases suddenly colour dark.
●
Engine failure warning light is on
5.2.4 Service
address
If you cannot correct a problem with the aid of the mal-
function table, contact your WhisperPower Service Centre
or WhisperPower Netherlands, tel: INT+31-512-571550.
www.whisperpower.eu.