redundant liquid will be pressed into the expansion tank.
This tank has to be filled up till the mark. When cooling
liquid is not available clean fresh water could be used with
an additive of anti-freeze. When using water with anti-
freeze the right mixture has to be calculated according to
the information of the supplier of the anti-freeze. When the
cooling is based on keel cooling or radiator cooling the
capacity of these coolers and piping has to be taken into
account calculating the right mixture. The cooling liquid in
the engine is pressurised and has a boiling point above
100° C. The temperature switch in the thermostat housing
switches at 110° C. When keel cooling or radiator cooling
is applied the cooling system is not pressurised. There
should be a special cap on the manifold without valves
leaving the connection to the expansion tank open. Refer
to the manual on keel cooling and radiator cooling.
2.5.13 Technical
data
Model
M-SC6 M-SC8 M-SC10
GENERAL
RPM
3000
3000
3000
Alternator
water cooled, synchronous
Engine: Mitsubishi diesel, model
L2E
L2E
L3E
Number of cylinders
2
2
3
Displacement
635 cm3
635 cm3
952 cm3
Bore X stroke
76x70 mm
76x70 mm
76x70 mm
Combustion air consumption
0.9 m3/min 0.9
m3/min 1,4
m3/min
Continuous power engine
5 kW
6,4 kW
10,5 kW
Cooling system
indirect cooling by raw water, 10-15 l/min.
Cooling water pump
PTO driven WhisperPower self priming impeller pump, type M
Fuel lift pump engine
electric pump (12 V DC), additional pump available upon request
Starting battery (optional)
60-90 Ah 12V
Fuel consumption
1.5-4 litre/hour, load dependent
Control
Digital Diesel Control including automatic start/stop
ELECTRICAL SPECIFICATIONS
Output voltage
230V 50 Hz alternating current (AC) single phase
Output rating at powerfactor cos phi = 1
5 kW
6,4 kW
9.4 kW
Voltage tolerance
± 5%
± 5%
± 5%
Frequency tolerance
± 5%
± 1% *
± 1% *
Alternator
brushless, two pole, synchronous
Voltage regulation:
capacitor
cap AVR (option)
cap AVR (option)
MECHANICAL SPECIFICATIONS
Supply includes
generating set, built into tugged GRP sound shield with steel base plate, mounted
on rubber anti vibration mounts
Dimensions hxwxd
660x495x550 mm
660x495x550 mm
810x525x615 mm
Colour
top white, bottom green
Weight (including canopy)
178 kg
182 kg;
210 kg
Max. installation angle
25 degrees
25 degrees
25 degrees
Standard supplies
remote panel (+15 m cable), fuel lift pump, expansion tank
Optional mobile
Installation kits, mobile (vehicle) version, non-earth return, spare part kits
* Electronic governor