MAINTENANCE
26
December 2010 / M-SC6/8/10 / EN
4.3.2
Putting out of service
When not using the generating set for a longer period it is
recommended to execute an engine preservation
procedure.
1
Clean the engine.
2 Loosen the fuel suction pipe and fuel return and put
them in a can with preservation diesel fuel. Start the
engine and run the engine warm.
3
Drain the hot engine oil and refill with preservation oil.
4 Stop the engine and take loose the inlet of the raw
water pump. Drain the water from the water lock.
Crank the engine having the raw water inlet sucking
anti-freeze from a can until the pump, heat exchanger
and manifold are filled.
5
The coolant can stay in the engine
6 Disconnect the battery and store it in a place free of
frost and dry and charge it regularly.
7
Close inlet- and outlet openings with tape.
8 Protect the generating set against the influences of
bad weather conditions.
This method of preservation will be sufficient for 6 months.
Repeat steps 2, 3, and 4, every 6 months. Change oil
before using the engine again.