Page 6 | 1-800-343-9463
SL 072820
CONTROLLER LAYOUT
Refer to page 18 for complete listing of buttons and symbols.
Slimline LS - Low Speed
Slimline LS - Medium Speed
Cellar Size (cu. ft.)*
300
650
BTU/h w/60°F condenser
air intake temperature
2601/1961
(total/sensible)
3032/2413
(total/sensible)
BTU/h w/75°F condenser
air intake temperature
2635/1951
(total/sensible)
2904/2309
(total/sensible)
BTU/h w/85°F condenser
air intake temperature
2396/1870
(total/sensible)
2612/2158
(total/sensible)
BTU/h w/95°F condenser
air intake temperature
2205/1704
(total/sensible)
2392/2008
(total/sensible)
Dimensions
21.5”L x 22.16”W x 10.33” H
Refrigerant
R-134a
HP
1/5
Voltage Rating
115V (15-amp dedicated circuit required)
Weight
81 lbs
Amps (running)
4.2
4.3
Drain Line
1/2” ID clear plastic tubing
Installation
Through the wall (above a doorway)
Thermostat
Advanced digital controller, liquid-temperature-measuring bottle probe
Temp. Delta
Can maintain a 55°F cellar temperature with up to 85°F condenser air intake temperature
Outside Venting
Not recommended
Warranty
Two-year limited warranty (parts and labor)
UNIT SPECIFICATIONS
* See note on next page
Compressor is On
Unit is in Anti-Frost
Mode
Fans are On
Alarm is present
Temperature Measurement
Menu Navigation
and Value Increase
(
Press and hold to manually
enter Anti-Frost mode
.)
Power On/Off
(hold for approx. 3 seconds)
and Escape
Menu Navigation
and Value Decrease
SET (ENTER)
(
Press and hold
to enter the
parameter menu
.)