Slimline LS
www.whisperkool.com | Page 13
STEP 6
Slide the cooling unit back in towards the
cellar and secure it to the wall through the pre-
drilled holes on the brackets. The screws should
penetrate the studs and/or frame. Seal all cracks
and gaps around the unit with an airtight sealant
or caulking to prevent air leakage.
Note: If you use decorative moulding, it should be
attached to the walls, never to the cooling unit itself.
STEP 7
Attach the condensate drain line
The condensation drain line tube is used to remove excess condensation from the unit to a proper discharge location.
It is important that the drain line tube be properly connected to prevent leakage and other problems associated with
excess condensation.
Note: To prevent mold from growing, allow the drain line to hang above the water line.
STEP 8
If removed, reinstall the grilles on both sides of the unit and plug in the power cord. The use of an extension cord is not
recommended.
INSTALLATION (continued)
Failure to install the drain line will void the warranty.
To prevent mold from growing, allow the drain line
to hang above the water line.
WRONG: Drain line
is under water.
Drain line is
above possible
water level