ETP String Component: Attribute
23
Control Blocks
Level
Faders
Attribute
SET /
SETL
GET /
GETL
INC /
DEC
Index1/
Index2
Value Range
Fader
Levels
FDRLVL
Y
Y
Y
Index1
-100 ~ 12 *
Mute
Fader
FDRMUTE
Y
Y
N
Index1
0 = unmuted
1 = muted
* Can contain a decimal number.
Presets
Attribute
SET /
SETL
GET /
GETL
INC /
DEC
Index1/
Index2
Value Range
Preset
PRESET
N
N
N
None
1001 to max
preset number
Note
: Instead of SET/SETL, GET/GETL, INC, or DEC; the preset attribute uses
RECALL as the Command. Preset numbers begin at 1001, regardless of preset name
(the first preset defined is 1001, the next 1002, and so forth).
Example: in the string: RECALL 1 PRESET 1001<LF>
We are telling E Desk to recall the first preset on an E Desk system. Since presets
apply to entire systems, or DAP files, the Device Number will always be 1 for Preset
strings.