WMAHV Single-Stage Cooling with Single- or 2-Stage Heating
Cooling Only—2-Stage Heat Thermostat
NOTES:
1. Y/Y2 enables high speed fan cooling.
2. E/W1 enables low speed fan heating. W/W2 enables high
speed fan heating.
3. OT1 PJ4 must be cut for this configuration.
4. Cut HUM PJ6 jumper if using humidistat. Humidistat opens
on humidity rise.
5. DIP Switch 4 must be in the “ON” position.
Cooling Only—2-Stage Heat—1
st
Room Thermostat and 2
nd
Outdoor Thermostat
NOTES:
■
1
st
Stage enabled through room thermostat.
■
2
nd
Stage enabled through closed outdoor thermostat.
1. Y/Y2 enables high speed fan cooling.
2. E/W1 enables low speed fan heating. E/W1 with outdoor
thermostat closed enables high speed fan heating.
3. OT1 PJ4 must be cut for this configuration.
4. Cut HUM PJ6 jumper if using humidistat. Humidistat opens
on humidity rise.
5. DIP Switch 4 must be in the “ON” position.
Goodman 6 Long
HIGH VOLTAGE!
WARNING
Disconnect ALL power before servicing.
Multiple power sources may be present.
Failure to do so may cause property damage, personal injury or death.
See Note 3
See Note 4
Room Thermostat
If Needed
Humidistat
(Optional)
See Note 4
Condensing Unit
2
nd
Stage Heater
1
st
Stage Heater
Please refer
to manual
for proper
DIP switch (CFM)
configuration.
To Comfort Alert
Module (If Used)
See Note 3
See Note 4
Condensing Unit
Outdoor Thermostat
Room Thermostat
2
nd
Stage Heater
1
st
Stage Heater
Humidistat
(Optional)
See Note 4
Please refer
to manual
for proper
DIP switch (CFM)
configuration.
If Needed
To Comfort Alert
Module (If Used)