Troubleshooting

Need help troubleshooting? Call Toll Free 1-866-986-3223

Monday- Friday, 8 AM - 7 PM EST

or visit www.whirlpoolwatersofteners.com

When you call, please be prepared to provide the model and serial number,

found on the rating decal, typically located on the rim below the salt lid hinges.

This check verifies proper operation of the valve

motor, brine tank fill, brine draw, regeneration flow

rates, and other controller functions.  Always make

the initial checks, and the manual initiated diagnos-

tics.

NOTE:

The electronic control display must show a

steady time (not flashing).  If an error code

shows, first press the PROGRAM button to

enter the diagnostic display.

1

. Press the RECHARGE button and hold in for 3

seconds.  RECHARGE begins to flash as the con-

ditioner’s valve advances from the service to fill

position.  Remove the brinewell cover and, using a

flashlight, observe fill water entering the tank.

If water does not enter the tank, look for an

obstructed nozzle, venturi, fill flow plug, brine tub-

ing, or brine valve riser pipe.

MANUAL ADVANCE REGENERATION CHECK

2

. After observing fill, press the RECHARGE button to

move the conditioner’s valve into the brine position.

A slow flow of water to the drain will begin.  Verify

brine draw from the brine tank by shining a flash-

light into the brinewell and observing a noticeable

drop in the liquid level.  This may take 15 to 20

minutes.

NOTE:

Be sure water is in contact with the salt, and

not separated by a salt bridge (See "Breaking

A Salt Bridge" section).

If the water conditioner does not draw brine, check

for (most likely to least likely):

=

Dirty or plugged nozzle and venturi, see

"Cleaning the Nozzle and Venturi" section.

=

Nozzle and venturi not seated on the gasket, or

gasket deformed.

=

Valve seals leaking (See Troubleshooting).

=

Restriction in valve drain, causing a back-pres-

sure (bends, kinks, elevated too high, etc.).  See

"Install Valve Drain Hose" section.

=

Obstruction in brine valve or brine tubing.

NOTE:

If water system pressure is low, a too-long or

elevated drain hose may cause back pres-

sure, stopping brine draw.  Avoid drain hose

runs longer than 30 feet.  Avoid elevating the

hose more than 8 feet above the floor.

3

. Press the RECHARGE button to move the condi-

tioner’s valve into the backwash position.  Look for

a fast flow of water from the drain hose.  Check

that the drain can adequately handle the flow and

volume.

An obstructed flow indicates a plugged top distribu-

tor, backwash flow plug, or drain hose.

4

. Press the RECHARGE button to move the condi-

tioner’s valve into the fast rinse position.  Again

look for a fast drain flow.  Allow the conditioner to

rinse for a few minutes to flush out any brine that

may remain in the resin tank from the brining cycle

test.

5

. To return the conditioner’s valve to the service

position, press the RECHARGE button.

RESETTING TO FACTORY DEFAULTS

To reset the electronic controller to its factory default

for all settings (time, hardness, etc.):

1

. Press the PROGRAM button and hold it until the

display changes twice to show the flashing model

code.

2

. Press the 

r

UP button (a few times, if necessary)

to display a flashing “SoS”.

3

. Press the PROGRAM button, and the electronic

controller will restart.

4

. Set the present time, hardness, etc., as described

on pages 13 & 14.

FIG. 38

Summary of Contents for WHESFC

Page 1: ... 866 986 3223 Monday Friday 8 AM 7 PM EST or visit www whirlpoolwatersofteners com When you call please be prepared to provide the model and serial number of your product found on the rating decal typically located on the rim below the salt lid hinges System tested and certified by NSF International against NSF ANSI Standard 42 for the reduction of chlorine taste and odor and Standard 44 for hardn...

Page 2: ... its listed rating or be operated at a sustained maximum service flow rate greater than its listed rating This system has been proven to deliver soft water for at least ten continuous minutes at the rated service flow rate The rated salt efficiency is measured by lab oratory tests described in NSF ANSI Standard 44 These tests represent the maximum possible efficiency that the system can achieve Op...

Page 3: ...ted by test data Variable Salt Dose The salt dose is selected by the electronic controls at regeneration time based on the amount needed SPECIFICATIONS Model WHESFC Model Code LLFC Rated Softening Capacity Grains Salt Dose 11 000 2 6 lbs 24 700 7 8 lbs 31 100 13 4 lbs Rated Efficiency Grains Pound of Salt Minimum Salt Dose 4 230 2 6 lbs Water Used During Regeneration Minimum Salt Dose 4 3 gal 1 00...

Page 4: ...ner Safety Your safety and the safety of others are very important We have provided many safety messages in this manual and on your appliance Always read and obey all safety messages This is the safety alert symbol This symbol alerts you to potential hazards that can kill or hurt you and others All safety messages will follow the safety alert symbol and either the word DANGER or WARNING These word...

Page 5: ...pears as small cloudy yellow orange or reddish suspended particles After the water stands for a period of time the particles settle to the bottom of the container Generally these irons are removed from water by filtra tion Chlorination is also recommended for bacterial iron Colloidal and inorganically bound iron is of ferric or fer rous form that will not filter or exchange out of water This water...

Page 6: ...amage voids the warranty To condition all water in the home install the water conditioner close to the water supply inlet and upstream of all other plumbing connections except outside water pipes Outside faucets should remain on hard water to avoid wasting conditioned water and salt A nearby drain is needed to carry away regenera tion discharge drain water Use a floor drain laundry tub sump standp...

Page 7: ...but still have water in house pipes Pipe fittings must be 3 4 minimum Use Copper pipe Threaded pipe PEX Crosslinked Polyethylene pipe CPVC plastic pipe Other pipe approved for use with potable water IMPORTANT Do not solder with plumbing attached to installation adaptors and single bypass valve Soldering heat will damage the adaptors and valve FIG 6 FIG 7 SINGLE BYPASS VALVE Pull out for Service So...

Page 8: ...bricated O ring Conditioned Water Hard Water Main Water Pipe Water Conditioner Valve Valve Drain Elbow Valve Drain Hose Do not connect the water conditioner valve drain tubing to the salt storage tank overflow hose Floor Drain Overflow Drain Elbow Salt Storage Tank Overflow Hose Secure Valve Drain Hose in place over Floor Drain 1 NPT Threaded Adaptor 1 1 2 air gap Dimensions FIG 8 39 1 2 47 7 8 3 ...

Page 9: ...lt in back or other injury TURN OFF WATER SUPPLY 1 Close the main water supply valve located near the well pump or water meter 2 Open all faucets to drain all water from house pipes NOTE Be sure not to drain water from the water heater as damage to the water heater ele ments could result INSTALL THE BRINE TANK OVERFLOW ELBOW Install the brine tank overflow grommet and elbow in the 13 16 diameter h...

Page 10: ...ank over flow elbow and secure in place with a hose clamp 2 Route the hose to the floor drain or other suitable drain point no higher than the drain fitting on the salt storage tank This is a gravity drain If the tank overfills with water the excess water flows to the drain point Cut the drain line to the desired length and route it neatly out of the way IMPORTANT For proper operation of the water...

Page 11: ...the home s faucets or water heater IMPORTANT To avoid water or air pressure damage to conditioner inner parts and to flush pipe chips or other residue from the water pipes be sure to do the following steps exactly as instructed 1 Make sure the water conditioner s valve drain hose is hooked up and the open end directed to a floor drain laundry tub or other suitable type of drain 2 The system should...

Page 12: ...at the plumbing connections that you made 7 Check for leaks around clips at conditioner s inlet and outlet If a leak occurs at a clip depressurize the plumbing turn off the water supply and open faucets before removing clip When removing clips at the conditioner s inlet or outlet push the single bypass valve body toward the conditioner See Figure 14 Improper removal may damage clips Do not reinsta...

Page 13: ...slowly advance the display Hold the buttons down for fast advance continued on next page STATUS LIGHT When the water conditioner is connected to electrical power the status light on the control panel will oper ate as follows Light flashing slowly along with the salt level indicators in the display The salt monitor sys tem indicates a low salt level and needs to be set See Set Salt Level on Page 15...

Page 14: ...s used NaCl or KCl Use the r UP or s DOWN buttons to toggle between NaCl and KCl then press the PROGRAM button to enter the selection 4 Press the PROGRAM button once again to return to normal operating display START A RECHARGE 1 Press the RECHARGE button and hold for three seconds until RECHARGE begins to flash in the display starting a recharge This recharge draws the sanitizing bleach into and t...

Page 15: ...ng until the recharge is completed will show in the display during all cycles except for the Fill cycle NOTE Avoid using hot water while the conditioner is regenerating because the water heater will refill with bypass hard water RECHARGE SCHEDULED If you do not want to start an immediate recharge but would like to schedule an extra recharge at the next preset recharge time do the following 1 Press...

Page 16: ... shipped with this feature set OFF 1 Press and hold the PROGRAM button until the screen in Figure 24 is displayed Once in this dis play press the PROGRAM button once and one of the two displays in Figure 25 is shown 2 Press the r UP or s DOWN buttons to set ON or OFF When set to ON the efficiency icon will be displayed in the lower left hand corner of the nor mal run display FIG 24 FIG 25 3 Press ...

Page 17: ...and screens The Clean Feature may be turned ON to provide an extra backwash that will help keep the cleansing screen clean The default is OFF IMPORTANT The cleansing feature is not intended to replace pretreatment filtration For problem water applications additional sediment filtration is recommended 2 Press the r UP or s DOWN buttons to set the number of days FIG 29 FIG 30 1 Press and hold the PR...

Page 18: ...the right hand side of the screen See Figure 32 The faster the water flow the faster the droplets will flash FIG 32 Droplets indicate water flow through conditioner Customizing Features Options POWER OUTAGE MEMORY If electrical power to the water conditioner is lost memory built into the timer circuitry will keep all set tings for several hours While the power is out the display is blank and the w...

Page 19: ...not recharged and hard water will result If the storage tank is full of salt it is difficult to tell if you have a salt bridge A bridge may be underneath loose salt Take a broom handle or like tool and hold it next to the water conditioner Measure the distance from the floor to the rim of the water conditioner Then gently push the broom handle straight down into the salt If a hard object is felt b...

Page 20: ...e valve into each cycle and check correct switch operation NOTE Be sure water is in contact with the salt and not separated by a salt bridge See Breaking A Salt Bridge section 5 While in this diagnostic screen the following infor mation is available and may be beneficial for vari ous reasons This information is retained by the computer from the first time electrical power is applied to the electro...

Page 21: ...onditioner does not draw brine check for most likely to least likely Dirty or plugged nozzle and venturi see Cleaning the Nozzle and Venturi section Nozzle and venturi not seated on the gasket or gasket deformed Valve seals leaking See Troubleshooting Restriction in valve drain causing a back pres sure bends kinks elevated too high etc See Install Valve Drain Hose section Obstruction in brine valv...

Page 22: ...8 7 6 5 22 Conditioner Exploded View 9 10 15 16 17 18 27 123 121 8 Valve Assembly See Pages 24 25 for parts 13 12 28 24 19 20 21 22 23 25 26 14 11 1 2 4 3 6 5 7 ...

Page 23: ...ovide the model and serial number found on the rating decal typically located on the rim below the salt lid hinges To order repair parts call toll free 1 866 986 3223 Monday Friday 8 am 7 pm EST Manufactured and warranted by Ecodyne Water Systems 1890 Woodlane Drive Woodbury MN 55125 Key No Part No Description 7112963 Distributor O Ring Kit includes Key Nos 1 3 1 á O Ring 2 7 8 x 3 1 4 2 á O Ring ...

Page 24: ...View wear strip seal cross section view 100 101 102 103 104 105 106 107 108 109 110 111 112 117 118 113 140 114 115 119 120 121 122 123 124 125 127 126 116 128 129 131 130 132 133 134 135 136 137 138 139 141 142 143 144 ...

Page 25: ...3 1 ea of Key Nos 124 125 124 á Turbine Support Shaft 125 á Turbine 126 7309811 Wire Harness Sensor 127 7081201 Retainer Nozzle Venturi 128 7171145 Valve Body 129 7342649 O Ring 1 4 x 3 8 pack of 2 130 1202600 Nut Ferrule 7257454 Nozzle Venturi Assembly incl Key Nos 127 129 131 139 131 7081104 Housing Nozzle Venturi 132 7095030 Cone Screen 133 1148800 Flow Plug 3 gpm 134 7114533 Nozzle Venturi Gas...

Page 26: ...sures not exceeding 125 psi and at water temperatures not exceeding 100 F provided further that the water conditioner is not subject to abuse mis use alteration neglect freezing accident or negligence and provided further that the water conditioner is not damaged as the result of any unusual force of nature such as but not limited to flood hurricane tornado or earthquake Warrantor is excused if fa...

Reviews: