MOVE THE WATER SOFTENER INTO PLACE
Excessive Weight Hazard
Use two or more people to move and install
water softener.
Failure to do so can result in back or other
injury.
8
Installation Instructions
TURN OFF WATER SUPPLY
1
. Close the main water supply valve, located near the
well pump or water meter.
2
. Open all faucets to drain all water from house pipes.
NOTE:
Be sure not to drain water from the water
heater, as damage to the water heater ele-
ments could result.
TYPICAL INSTALLATION
FIG. 9
NOTE:
See “Air Gap Requirements” section.
NOTE:
Water Softener shown with Salt Lid and
Top Cover removed
Inlet
Outlet
Clips
Pipe
To Outside
Faucets
1” NPT Sweat
Adaptor (not
included)
O-ring
Single
Bypass Valve
Lubricated
O-ring
Conditioned
Water
Hard Water
Main Water Pipe
Water Softener
Valve
Valve Drain
Elbow
Valve Drain
Hose*
*Do not connect the
water softener valve drain
tubing to the salt storage
tank overflow hose.
Floor Drain
Overflow
Drain Elbow
Salt Storage
Tank Overflow
Hose*
Secure Valve Drain Hose
in place over Floor Drain
1” NPT
Threaded
Adaptor
1-1/2”
air gap
Plug-in
Power
Supply
To
Controller
1
. Move the water softener into the desired location.
Set it on a solid, level surface.
IMPORTANT:
Do not place shims directly under the
salt storage tank to level the softener.
The weight of the tank, when full of
water and salt, may cause the tank to
fracture at the shim.
2
. Visually check and remove any debris from the
water softener valve inlet and outlet ports.
3
. Make sure the turbine assembly spins freely in the
"out" port of the valve.
4
. If not already done, put a light coating of silicone
grease on the single bypass valve o-rings.
5
. Push the single bypass valve into the softener valve
as far as it will go. Snap the two large holding clips
into place, from the top down as shown in Figures
11 & 12.
IMPORTANT:
Be sure the clips snap firmly into place
so the single bypass valve will not pull
out.