3
Clean Before Using
After you remove all of the package materials, clean the inside of
your refrigerator before using it. See the cleaning instructions in
“Refrigerator Care.”
Location Requirements
To ensure proper ventilation for your refrigerator, allow for a
¹⁄₂
"
(12.70 mm) space on each side. Allow 3" (7.5 cm) of space
between overhead cabinets and refrigerator top. Allow at least 1"
(25.40 mm) between back of cabinet and the wall. If your
refrigerator has an ice maker, make sure you leave some extra
space at the back for the water line connections.
■
If you are installing your refrigerator next to a fixed wall, leave
2" (5.08 cm) minimum on the hinge side (depending on your
model) to allow for the door to swing open.
■
Level the refrigerator. See “Adjust the Doors.”
NOTE: It is recommended that you do not install the refrigerator
near an oven, radiator, or other heat source. Do not install in a
location where the temperature will fall below 55°F (13°C).
Electrical Requirements
Before you move your refrigerator into its final location, it is
important to make sure you have the proper electrical connection.
Recommended Grounding Method
A 115 Volt, 60 Hz., AC only 15- or 20-amp fused, grounded
electrical supply is required. It is recommended that a separate
circuit serving only your refrigerator be provided. Use an outlet
that cannot be turned off by a switch. Do not use an
extension cord.
NOTE: Before performing any type of installation, cleaning, or
removing a light bulb, turn cooling off and/or disconnect the
refrigerator from the electrical source.
Style 1 - Dial control models. Turn the control to OFF and then
disconnect the refrigerator from the electrical source.
Style 2 - Electronic control models. Disconnect the refrigerator
from the electrical source.
When you are finished, reconnect the refrigerator to the electrical
source and reset the control to the desired setting. See “Using the
Control(s).”
Water Supply Requirements
Read all directions before you begin.
IMPORTANT:
■
If you turn the refrigerator on before the water line is
connected, turn the ice maker OFF.
■
All installations must meet local plumbing code requirements.
■
Use copper tubing and check for leaks. Install copper tubing
only in areas where the household temperatures will remain
above freezing.
TOOLS NEEDED: Flat-blade screwdriver,
⁷⁄₁₆
" and
¹⁄₂
" open-end
wrenches or 2 adjustable wrenches,
¹⁄₄
" nut driver and drill bit,
cordless drill. Gather the required tools and parts before starting
installation. Read and follow the instructions provided with any
tools listed.
NOTE: Your refrigerator dealer has a kit available with a
¹⁄₄
"
(6.35 mm) saddle-type shutoff valve, a union, and copper tubing.
Before purchasing, make sure a saddle-type valve complies with
your local plumbing codes. Do not use a piercing-type or
³⁄₁₆
"
(4.76 mm) saddle valve which reduces water flow and clogs more
easily.
Water Pressure
A cold water supply with water pressure of between 30 and
120 psi (207 and 827 kPa) is required to operate the ice maker. If
you have questions about your water pressure, call a licensed,
qualified plumber.
Important information to know about glass shelves
and covers:
Do not clean glass shelves or covers with warm water when
they are cold. Shelves and covers may break if exposed to
sudden temperature changes or impact, such as bumping.
Tempered glass is designed to shatter into many small,
pebble-size pieces. This is normal. Glass shelves and covers
are heavy. Use both hands when removing them to avoid
dropping.
WARNING
Explosion Hazard
Keep flammable materials and vapors, such as
gasoline, away from refrigerator.
Failure to do so can result in death, explosion, or fire.
3" (7.5 cm)
2" (5.08 cm)
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING