![Whirlpool W11296289 Service Manual Download Page 33](http://html.mh-extra.com/html/whirlpool/w11296289/w11296289_service-manual_972873033.webp)
For Service Technician Use Only
COMPONENT TESTING
Whirlpool
®
, Maytag
®
, Amana
®
, & IKEA
®
Refrigerators
n
3-3
Wiring Diagram
Wiring diagram A for models:
WRS321SDHB, WRS321SDHB01, WRS321SDHB02, WRS321SDHV, WRS321SDHV01, WRS321SDHV02, WRS321SDHW, WRS321SDHW01,
WRS321SDHW02, WRS321SDHZ, WRS321SDHZ01, WRS321SDHZ02, WRS325SDHB, WRS325SDHB01, WRS325SDHB02, WRS325SDHV,
WRS325SDHV01, WRS325SDHV02, WRS325SDHW, WRS325SDHW01, WRS325SDHW02, WRS325SDHZ, WRS325SDHZ01, WRS321SDHB,
WRS321SDHB00, WRS321SDHV, WRS321SDHV00, WRS321SDHW, WRS321SDHW00, WRS321SDHZ, WRS321SDHZ00, WRS325SDHB,
WRS325SDHB00, WRS325SDHV, WRS325SDHV00, WRS325SDHW, WRS325SDHW00, WRS325SDHZ, WRS325SDHZ00.
VOLTAGE TEST POINTS THESEUS
MAIN
CONTROL
(ACU)
CONNECTOR
FROM
COLOR
TO
COLOR
SPECIFICATIONS
P1
P1-1
BK
P1-2
WH
120 VAC Input constant from Power Cord
P1-2
WH
P1-4
RD
120 VAC Output to Compressor/Condenser Fan when cooling
P2
P2-1
YL/RD
P1-1
BK
120 VAC Input FC Light switch feedback
P2-4
YL
P1-1
BK
120 VAC Input FC Light switch feedback
P2-6
RD/WH
P1-2
WH
120 VAC Output to Evaporator Fan when cooling
P2-7
BR
P1-2
WH
120 VAC Output Defrost Heater when defrosting
P3
P3-4
V
P1-2
WH
120 VAC Output to Water Valve when water dispensing
P3-5
LB
P1-1
BK
120 VAC Input FC Door switch
P3-6
GY/OR
P1-2
WH
120 VAC Output to Cube Solenoid when dispensing cube
P3-8
BU
P1-2
WH
120 VAC Output to Auger Motor when dispensing ice
P4
P4-1
OR
P4-4
LB
12.7 VDC Output to User Interface
P4-3 GY
DATA COMMUNICATION
P5
P5-1
GY
P5-2
GY
5 VDC Input RC Thermistor
P5-3
TN
P5-4
TN
5 VDC Input FC Thermistor
P8
P8-1
PK
P8-2
PK
5 VDC Input Defrost Thermistor
P8-7
V
P8-8
RD
12.7 VDC Output to Dispenser LED
P70
P70-7 BU
12 VDC Pulse Damper Stepper Motor coil A +
P70-8 BH
12 VDC Pulse Damper Stepper Motor coil A -
P11
P11-1 YL
12 VDC Pulse Damper Stepper Motor coil B +
P11-2 RD
12 VDC Pulse Damper Stepper Motor coil B -
P11-3
BR
P11-4
BR
12 VDC Output to damper Heater
VOLTAGE TEST POINTS MINOTAUR
HMI
J1
J1-1
LB
J1-4
OR
12.7 VDC Output to User Interface
J1-2 GY
DATA COMMUNICATION