Recessed Area and Closet Installation Instructions
This dryer may be installed in a recessed area or closet.
For recessed area and closet installations, minimum clearances
can be found on the warning label on the rear of the dryer.
The installation spacing is in inches and is the minimum
allowable. Additional spacing should be considered for ease
of installation, servicing, and compliance with local codes
and ordinances.
If closet door is installed, the minimum unobstructed air opening
in the top and bottom is required. Louvered doors with equivalent
air openings are acceptable.
The dryer must be exhausted outdoors.
No other fuel-burning appliance may be installed in the same
closet as the dryer.
Minimum Installation Clearances
*Additional clearances for wall, door, and floor moldings may be required
or if external exhaust elbow is used.
Closet
door
Front
View
3" (76 mm)
3" (76 mm)
24 in
2
(1.55 m
2
)*
48 in
2
.
(3.10 m
2
)*
*Opening is the minimum for a closet door.
Louvered doors with equivalent air openings are acceptable.
Product Dimensions 27" (68.6 cm) dryer
Recessed front view
Closet side view
Closet
door
14"
(356 mm)
max.
1" (25 mm)
0" (0 mm)
15"
(381 mm)*
2" (51 mm)
0" (0 mm)
28
3
⁄
4
"
(733 mm)
ELECTRIC
GAS
EXHAUST
LEFT OR
RIGHT SIDE
EXHAUST
3
1
⁄
4
"
(83 mm)
1
1
⁄
4
"
(32 mm)
BACK
VIEW
4
1
⁄
4
"
(108 mm)
5
7
⁄
8
"
(152 mm)
4" (102 mm)
dia.
1"
(25 mm)
SIDE VIEW
BOTTOM
EXHAUST
35"
(889 mm)
27
1
⁄
4
" (695 mm)
29" (736 mm)
13
1
⁄
2
"
(343 mm)
3
1
⁄
2
"
(89 mm)
10
1
⁄
4
"
(260 mm)
27" (686 mm)
13"
(330 mm)
6
1
⁄
4
"
(159 mm)
Closet
door