5-3
BAKE ELEMENT
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
WARNING
6 INCH & 8 INCH COIL ELEMENTS
Refer to page 4-9 for the procedure for servic-
ing the bake element.
1. Unplug range or disconnect power.
2. Disconnect one of the wires from the bake
element terminals.
3. Set the ohmmeter to the R x 1 scale.
4. Touch the ohmmeter test leads to the bake
element terminals. The meter should indicate
between 21 and 33 Ω.
Refer to page 4-4 for the procedure for servic-
ing the coil element.
1. Unplug range or disconnect power.
2. Push and lift the element from the terminal
block.
3. Set the ohmmeter to the R x 1 scale.
4. Touch the ohmmeter test leads to the coil
element terminals. The meter should indicate
between 42 and 50 Ω on 6 inch coil element,
and 22 and 26 Ω on 8 inch coil element.