background image

6

Make electrical
connection

Electrical Shock Hazard

Disconnect power before making
electrical connections.

Connect ground wire to green
ground screw in terminal box.

Failure to do so can result in
death or electrical shock.

WARNING

15.

Depress both sides of the

light lens until tabs disengage
from slots in hood and remove
lens.

Install two 40 watt (maximum)
type A-15 appliance bulbs.

Reinstall light lens. Depress both
sides of lens, insert tabs into slots
and release.

16.

For non-vented

installations:

Grasp tab at front

center of filter. Push toward back
to release filter from spring clips
at front. Pull down then froward
to remove aluminum mesh filter.

Install non-vented filter
(purchased separately) by
inserting into channel at back of
compartment. Grasp tab and pull
forward so that filter snaps under
spring clips at front.

14.

Direct wiring:

Connect the white and black wires
of the power supply cable to the
white and black leads in the hood
with twist-on connectors.

Connect the power supply ground
wire to the green ground screw
inside the terminal box.

Use caulking to seal wire opening.

Replace terminal box cover.

Using a U.L.-listed power
supply cord-connection kit 
(U.S. only):

Follow Power Cord Kit instructions for
connecting wiring.

To get the most efficient

use from your new range

hood, read the “Use and

Care Information” section.

Keep your Whirlpool

Installation Instructions and

Use and Care Guide close

to range hood for easy

reference.

white

green ground 

screw

ground
wire

black

8.

Lift the range hood up under

cabinet and determine final
position. Mark on the underside
of cabinet the location of the four
keyhole mounting slots. Set
range hood aside on a protected
surface.

keyhole slot

front 
of hood

9.

Use 1/8" (or 3 mm) drill bit

and drill 4 pilot holes as shown.

drill pilot hole

10.

Remove the 4 hood

mounting screws from the parts bag
and install in pilot holes. Leave
screw heads away from shim
strips about 1/4" (6.4 cm)

11.

If using direct wiring, make

sure power is disconnected, and pull
about 12" (30 cm) of wire through
wall or cabinet and into opening.

12.

Lift range hood into final

position, feeding electrical wire
through wiring opening. Position the
range hood so that the large end of
the keyhole slots are over the
screws. Then push the hood toward
the wall so that the screws are in the
neck of the slots. Tighten mounting
screws to cabinet, making sure
mounting screws are in narrow neck
of slots. Make sure that damper
blade, if used, rotates up and down
freely.

13.

Connect ventwork to hood.

Seal joints with duct tape to make
the secure and air tight.
Note: Damper/vent connector and
round vent plate can be installed
up to 1/2" (12.7 mm) on either
side of hood center if ventwork is
off-center. In extreme off-center

1/4" 

(6.4 mm)

installations, one end of the vent
connector may need to be
trimmed to clear the electrical
strain relief.

Summary of Contents for RH4830 Series

Page 1: ...ference Save Installation Instructions for local electrical inspector s use 628013A 9763369 RH4830 Series RH4836 Series www whirlpool com Quick Reference Table of Contents Pages Before you start Electrical requirements Product dimensions Venting requirements Installation steps Use and Care Information Warranty Requesting Assistance or Service 2 2 3 3 4 4 6 7 8 8 9 10 30 76 2 cm and 36 91 4 cm Conv...

Page 2: ...iety of Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities Ducted fans must always be vented to the outdoors WARNING To reduce the risk of fire use only metal ductwork This unit must be grounded flat blade screwdriver pliers drill ruler 1 1 4 3 0 cm drill...

Page 3: ...fore installing the hood NOTE If a non vented recirculating installation is desired follow instructions on Page 5 The length of the vent system and number of elbows should be kept to a minimum to provide efficient performance The size of the vent system should be uniform Do Not install two elbows together Use duct tape to seal all joints in the vent system Vent system can terminate either through ...

Page 4: ...cm to 7 17 8 cm 4 5 ft 1 4 m 90 elbow 5 ft 1 5 m 45 elbow 2 5 ft 0 8 m 3 1 4 x 10 8 3 x 25 4 cm to 7 17 8 cm 90 elbow 5 ft 1 5 m 7 17 8 cm wall cap 0 ft 0 m Slide cardboard or hardboard under range before moving range across floor to prevent damaging floor covering Cover countertop cooktop or set in range with a thick protective covering to prevent damaging them 1 Disconnect and move freestanding ...

Page 5: ... front 5 1 4 13 3 cm 7 1 2 19 1 cm 3 4 1 9 cm 1 1 4 3 2 cm dia hole 7 17 8 cm ROUND VERTICAL vent system 5 12 7 cm centerline wall 7 1 2 19 1 cm 2 5 1 cm 1 1 4 3 2 cm dia hole 8 20 3 cm dia hole Excessive Weight Hazard Use two or more people to move and install range hood Failure to do so can result in back or other injury WARNING terminal box cover 7a For vented installations Insert the baffle pl...

Page 6: ...rmation section Keep your Whirlpool Installation Instructions and Use and Care Guide close to range hood for easy reference white green ground screw ground wire black 8 Lift the range hood up under cabinet and determine final position Mark on the underside of cabinet the location of the four keyhole mounting slots Set range hood aside on a protected surface keyhole slot front of hood 9 Use 1 8 or ...

Page 7: ...an size Always use cookware appropriate for the size of the surface element WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE FOLLOWING SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the flames do not go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT NEVER PICK UP A ...

Page 8: ...ly household use 4 Damage resulting from accident alteration misuse abuse fire flood acts of God improper installation installation not in accordance with electrical or plumbing codes or use of products not approved by Whirlpool 5 Any food loss due to refrigerator or freezer product failures 6 Replacement parts or repair labor costs for units operated outside the United States or Canada 7 Pickup a...

Page 9: ... area call our Customer Interaction Center telephone number your nearest authorized service center or Whirlpool Factory Service at 1 800 442 1111 For further assistance If you need further assistance you can write to ask any questions or tell us about your concerns at Customer Interaction Center c o Correspondence Dept 2000 North M 63 Benton Harbor MI 49022 2692 Please include a daytime phone numb...

Page 10: ...in ONTARIO QUEBEC Montreal except South Shore 1 800 361 3032 South Shore Montreal 1 800 361 0950 Quebec City 1 800 463 1523 Sherbrooke 1 800 567 6966 ATLANTIC PROVINCES 1 800 565 1598 For further assistance If you need further assistance you can write to Inglis Limited with any questions or concerns at Consumer Relations Department Inglis Limited 1901 Minnesota Court Mississauga Ontario L5N 3A7 Pl...

Page 11: ...es instructions d installation à l intention de l inspecteur local des installations électriques 628013A 9763369 www whirlpool com Consultation rapide Table des matières Pages Avant de commencer Spécifications pour l installation électrique Dimensions du produit Circuit de décharge de l air Les étapes de l installation Utilisation et entretien Garantie Demande d assistance ou de service 2 3 3 3 4 ...

Page 12: ...t de 3 cm 1 1 4 po foret de 3 mm 1 8 po pour les avant trous crayon Matériel nécessaire pour l installation avec décharge à l extérieur compas ou gabarit circulaire de 20 3 cm 8 po cisaille de ferblantier scie à guichet scie sauteuse ruban adhésif pour conduit clapet rond de 17 8 cm 7 po pour un conduit d évacuation de diamètre 17 8 cm 7 po Placards avec fond en retrait tringles de remplissage de ...

Page 13: ... extrémité du câble d alimentation sur la hotte et sur la boîte de connexion Le système doit décharger l air à l extérieur Ne pas terminer le conduit d évacuation au dessus d un plafond ou dans autre espace fermé Ne pas utiliser une bouche de décharge murale de 10 2 cm 4 po normalement utilisée pour un équipement de buanderie Ne pas utiliser des conduits de plastique Le système d évacuation nécess...

Page 14: ...rotecteur épais sur la table de cuisson ou le plan de travail pour la protection contre les dommages et souillures 3 Si le placard comporte un fond en retrait ajouter une tringle de remplissage de chaque côté Positionner les vis de fixation des tringles aux emplacements indiqués 2 Déterminer quelle méthode de décharge de l air sera utilisée à travers le toit à travers le mur ou sans évacuation Lor...

Page 15: ...us de personnes pour déplacer et installer de la hotte Le non respect de cette instruction peut causer une blessure au dos ou d autres blessures AVERTISSEMENT couvercle de la boîte de connexion bossages de positionnement plaque de separation 7a Installation avec décharge à l extérieur Insérer la plaque de séparation dans le logement derrière la grille Les bossages de positionnement doivent être au...

Page 16: ...est pas parfaitement centré par rapport à la hotte on peut déplacer le raccord de connexion d un côté ou de l autre 15 Appuyer sur les deux côtés du diffuseur de lumière pour dégager les pattes de retenue de leur logement dans la hotte enlever le diffuseur Installer une lampe de 40 watts maximum type A 15 pour appareils ménagers Réinstaller le diffuseur de lumière Appuyer sur les deux côtés du dif...

Page 17: ...et à la quantité des aliments à préparer et à la taille de l élément chauffant AVERTISSEMENT POUR RÉDUIRE LE RISQUE DE DOMMAGES CORPORELS APRÈS LE DÉCLENCHEMENT D UN FEU DE GRAISSE SUR LA CUISINIÈRE APPLIQUER LES RECOMMANDATIONS SUIVANTES Placer sur le récipient un couvercle bien ajusté une tôle à biscuits ou un plateau métallique POUR ÉTOUFFER LES FLAMMES puis éteindre le brûleur VEILLER À ÉVITER...

Page 18: ...4 Les dommages imputables à accident modification usage impropre ou abusif incendie inondation actes de Dieu installation fautive ou installation non conforme aux codes d électricité ou de plomberie ou l utilisation de produits non approuvés par Whirlpool 5 Toute perte d aliments due à une défaillance du réfrigérateur ou du congélateur 6 Le coût des pièces de rechange et de la main d œuvre pour le...

Page 19: ...ez à notre Centre d interaction avec la clientèle votre Centre de service autorisé le plus proche ou le service de l usine Whirlpool en composant le 1 800 442 1111 Pour plus d assistance Si vous avez besoin de plus d assistance vous pouvez écrire en soumettant toute question ou problème au Customer Interaction Center c o Correspondence Dept 2000 North M 63 Benton Harbor MI 49022 2692 Veuillez indi...

Page 20: ...indicatif régional 807 en ONTARIO QUÉBEC Montréal à l exception de la rive sud 1 800 361 3032 Rive Sud Montréal 1 800 361 0950 Québec 1 800 463 1523 Sherbrooke 1 800 567 6966 PROVINCES DE L ATLANTIQUE 1 800 565 1598 Pour plus d assistance Si vous avez besoin d autre assistance vous pouvez écrire à Inglis Ltée en soumettant toute question ou préoccupation au Service des relations avec la clientèle ...

Reviews: