background image

Prepare and install
the hood 

3-1/4" x 10" (8.3 x 25.4 cm)

RECTANGULAR VERTICAL 

vent system

5

4.

From the diagrams below,

select the diagram for your
installation.

Vented installations:

Cut the vent

system and electrical wiring
access holes as required. Either
wiring hole can be used.

Non-vented installations:

Cut only

the one 1-1/4" (3.2 cm) dia. wiring
access hole required. If wiring
through the top, use location
shown in VERTICAL vent systems.
If wiring through the back, use
location shown in HORIZONTAL
vent system.

5.

Remove terminal box cover.

Depending on your installation,
remove either back or  top wiring
knockout.

8.

Lift the range hood up under

cabinet and determine final
position. Mark on the underside
of cabinet the location of the four
keyhole mounting slots. Set
range hood aside on a protected
surface.

7a.

For vented installations:

Check that the louver cover is
installed in front of hood.

Remove either top or rear
rectangular vent knockout. If
using round vent, remove both
top rectangular and semi-circular
knockouts.

7b.

If using rectangular vent,

attach rectangular damper/vent
connection. Note: If the wall cap
is directly behind the vent
connector, the dampers in the
connector and wall cap MUST
NOT interfere with each other.
Remove the vent connector
damper if they interfere.

7c.

For non-vented

installations:

Remove louver

cover from front of hood.

6.

Remove the rectangular

damper/vent connector from
hood. Set connector and screws
aside for use if connecting to a
rectangular vent system.

For vented installations, go to
Step 7a.

For non-vented installations,
go to Step 7c.

1-1/2"
(3.8 cm)

5-1/2" 
(14 cm)

centerline

wall

5-1/4"
(13.3 cm)

7-1/2"
(19.1 cm)

2" 
(5.1 cm)

1-1/4"
(3.2 cm)
dia. hole

3-1/4" x 10" (8.3 x 25.4 cm)

HORIZONTAL 

vent system

1/8" 
(3.2 mm)

3-3/4" 
(9.5 cm)

centerline

cabinet

front

5-1/4"
(13.3 cm)

7-1/2"
(19.1 cm)

3/4" 
(19 mm)

1-1/4" (3.2 cm)
dia. hole

7" (17.8 cm) 

ROUND VERTICAL 

vent system

5" 

(12.7 cm)

centerline

wall

7-1/2"
(19.1 cm)

2" 
(5.1 cm)

1-1/4" 
(3.2 cm) 
dia. hole

8" (20.3 cm)
dia. hole

Excessive Weight Hazard

Use two or more people to move
and install range hood.

Failure to do so can result in
back or other injury.

WARNING

terminal
box cover

keyhole slot

front 
of hood

9.

Use 1/8" (or 3 mm) drill bit

and drill 4 pilot holes as shown.

drill pilot hole

10.

Remove the 4 hood

mounting screws from the parts bag
and install in pilot holes. Leave
screw heads away from filler
strips or cabinet bottom about
1/4" (6.4 cm)

11.

If using direct wiring, make

sure power is disconnected, and pull
about 12" (30 cm) of wire through
wall or cabinet and into opening.

12.

Lift range hood into final

position, feeding electrical wire
through wiring opening. Position the
range hood so that the large end of
the keyhole slots are over the
screws. Then push the hood toward
the wall so that the screws are in the
neck of the slots. Tighten mounting
screws to cabinet, making sure
mounting screws are in narrow neck
of slots. Make sure that damper
blade, if used, rotates up and down
freely.

13.

Connect ventwork to hood.

Seal joints with duct tape to make
the secure and air tight.

1/4" 

(6.4 mm)

YL20378/8285186  6/18/02  10:43 AM  Page 5

Summary of Contents for RH3730 Series

Page 1: ...stallation Instructions for local electrical inspector s use Part No 626918A 8285186 Pièce N 626918A 8285186 RH3730 Series RH3736 Series www whirlpool com Quick Reference Table of Contents Pages Before you start Electrical requirements Product dimensions Venting requirements Installation steps Use and Care Information Warranty Requesting Assistance or Service 2 2 3 3 4 6 7 8 8 9 10 30 76 2 cm and ...

Page 2: ...itioning Engineers ASHRAE and the local code authorities When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities Ducted fans must always be vented to the outdoors WARNING To reduce the risk of fire use only metal ductwork This unit must be grounded flat blade screwdriver pliers drill ruler 1 1 4 3 0 cm drill bit 1 8 or 3 mm drill bit for pilot holes...

Page 3: ...od NOTE If a non vented recirculating installation is desired follow instructions on Page 5 The length of the vent system and number of elbows should be kept to a minimum to provide efficient performance The size of the vent system should be uniform Do Not install two elbows together Use duct tape to seal all joints in the vent system Vent system can terminate either through the roof or wall Use c...

Page 4: ...4 cm to 7 17 8 cm 4 5 ft 1 4 m 90 elbow 5 ft 1 5 m 45 elbow 2 5 ft 0 8 m 3 1 4 x 10 8 3 x 25 4 cm to 7 17 8 cm 90 elbow 5 ft 1 5 m 7 17 8 cm wall cap 0 ft 0 m Slide cardboard or hardboard under range before moving range across floor to prevent damaging floor covering Cover countertop cooktop or set in range with a thick protective covering to prevent damaging them 1 Disconnect and move freestandin...

Page 5: ...onnector and screws aside for use if connecting to a rectangular vent system For vented installations go to Step 7a For non vented installations go to Step 7c 1 1 2 3 8 cm 5 1 2 14 cm centerline wall 5 1 4 13 3 cm 7 1 2 19 1 cm 2 5 1 cm 1 1 4 3 2 cm dia hole 3 1 4 x 10 8 3 x 25 4 cm HORIZONTAL vent system 1 8 3 2 mm 3 3 4 9 5 cm centerline cabinet front 5 1 4 13 3 cm 7 1 2 19 1 cm 3 4 19 mm 1 1 4 ...

Page 6: ...ure damper operates freely 14 Direct wiring Connect the white and black wires of the power supply cable to the white and black leads in the hood with twist on connectors Connect the power supply ground wire to the green ground screw inside the terminal box Use caulking to seal wire opening Replace terminal box cover Using a U L listed power supply cord connection kit U S only Follow Power Cord Kit...

Page 7: ...securely fasten a prominent warning device such as a tag to the service panel CAUTION For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors WARNING TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE Never leave surface units unattended at high settings Boilovers cause smoking and greasy spillovers that may ignite Heat oils slowly on low or medium settings Al...

Page 8: ...To clean filter light lens Place filter light lens in dishwasher or hot sudsy water to clean Non vented installation Turn filter light lens so that charcoal filter pad is facing up Lift tabs and remove charcoal filter pad Discard charcoal filter pad if it needs replacing Place filter light lens in dishwasher or hot sudsy water to clean Lift tabs and place charcoal filter pad in filter light lens T...

Page 9: ... area call our Customer Interaction Center telephone number your nearest authorized service center or Whirlpool Factory Service at 1 800 442 1111 For further assistance If you need further assistance you can write to ask any questions or tell us about your concerns at Customer Interaction Center c o Correspondence Dept 2000 North M 63 Benton Harbor MI 49022 2692 Please include a daytime phone numb...

Page 10: ...UEBEC Montreal except South Shore 1 800 361 3032 South Shore Montreal 1 800 361 0950 Quebec City 1 800 463 1523 Sherbrooke 1 800 567 6966 ATLANTIC PROVINCES 1 800 565 1598 For further assistance If you need further assistance you can write to Inglis Limited with any questions or concerns at Consumer Relations Department Inglis Limited 1901 Minnesota Court Mississauga Ontario L5N 3A7 Please include...

Page 11: ... d installation à l intention de l inspecteur local des installations électriques Pièce N 626918A 8285186 Part No 626918A 8285186 www whirlpool com Consultation rapide Table des matières Pages Avant de commencer Spécifications pour l installation électrique Dimensions du produit Circuit de décharge de l air Les étapes de l installation Utilisation et entretien Garantie Demande d assistance ou de s...

Page 12: ...m 1 1 4 po foret de 3 mm 1 8 po pour les avant trous crayon Matériel nécessaire pour l installation avec décharge à l extérieur compas ou gabarit circulaire de 20 3 cm 8 po cisaille de ferblantier scie à guichet scie sauteuse ruban adhésif pour conduit clapet rond de 17 8 cm 7 po pour un conduit d évacuation de diamètre 17 8 cm 7 po Placards avec fond en retrait tringles de remplissage de largeur ...

Page 13: ...tiliser une bouche de décharge murale de 10 2 cm 4 po normalement utilisée pour un équipement de buanderie Ne pas utiliser des conduits de plastique Le système d évacuation nécessaire pour l installation n est pas inclus Déterminer la méthode appropriée pour la décharge à l extérieur On recommande que le conduit de décharge soit installé avant l installation de la hotte NOTE Pour une configuration...

Page 14: ...au protecteur épais sur la table de cuisson ou le plan de travail pour la protection contre les dommages et souillures 3 Si le placard comporte un fond en retrait ajouter une tringle de remplissage de chaque côté Positionner les vis de fixation des tringles aux emplacements indiqués 2 Déterminer quelle méthode de décharge de l air sera utilisée à travers le toit à travers le mur ou sans évacuation...

Page 15: ...tangulaire supérieur et les opercules semi circulaires 7b Pour un conduit d évacuation rectangulaire installer le raccord rectangulaire clapet Note Si la bouche de décharge murale est située directement derrière le raccord on doit veiller à ce qu il n y ait PAS d interférence entre le clapet dans le raccord et la bouche de décharge 10 Prendre les 4 vis de montage dans le sachet de petites pièces p...

Page 16: ... ventilateur et des lampes Vérifier que le volet de réglage peut manœuvrer librement 14 Raccorder les conducteurs du câble d alimentation de la hotte aux conducteurs de même couleur du circuit électrique avec des connecteurs vissables blanc blanc et noir noir Ensuite connecter le conducteur de liaison à la terre à l intérieur de la boîte de connexion de la hotte avec la vis verte Assurer l étanché...

Page 17: ...t à la quantité des aliments à préparer et à la taille de l élément chauffant AVERTISSEMENT POUR RÉDUIRE LE RISQUE DE DOMMAGES CORPORELS APRÈS LE DÉCLENCHEMENT D UN FEU DE GRAISSE SUR LA CUISINIÈRE APPLIQUER LES RECOMMANDATIONS SUIVANTES Placer sur le récipient un couvercle bien ajusté une tôle à biscuits ou un plateau métallique POUR ÉTOUFFER LES FLAMMES puis éteindre le brûleur VEILLER À ÉVITER ...

Page 18: ...u chaude savonneuse Installation avec recyclage Orienter l ensemble filtre diffuseur pour placer le filtre à charbon vers le haut pour exposer le filtre Tirer vers le haut sur les pattes et retirer le filtre à charbon On doit jeter le filtre à charbon et installer un filtre neuf Pour le nettoyage placer le filtre diffuseur dans le lave vaisselle ou dans de l eau chaude savonneuse Tirer sur les pat...

Page 19: ...ez à notre Centre d interaction avec la clientèle votre Centre de service autorisé le plus proche ou le service de l usine Whirlpool en composant le 1 800 442 1111 Pour plus d assistance Si vous avez besoin de plus d assistance vous pouvez écrire en soumettant toute question ou problème au Customer Interaction Center c o Correspondence Dept 2000 North M 63 Benton Harbor MI 49022 2692 Veuillez indi...

Page 20: ... en ONTARIO QUÉBEC Montréal à l exception de la rive sud 1 800 361 3032 Rive Sud Montréal 1 800 361 0950 Québec 1 800 463 1523 Sherbrooke 1 800 567 6966 PROVINCES DE L ATLANTIQUE 1 800 565 1598 Pour plus d assistance Si vous avez besoin d autre d assistance vous pouvez écrire à Inglis Ltée en soumettant toute question ou préoccupation au Service des relations avec la clientèle Inglis Ltée 1901 Min...

Reviews: