600-900 mm
first to remove any dirt. Otherwise this could
clog the intake filter in the machine and block
the water supply.
WATER INTAKE – MIXED OR COLD WATER
On delivery the machine is set to use mixed hot
and cold water (E).
The machine can be set for cold water intake
only. This setting must be made by a qualified
professional. Contact the service division.
To change the water intake setting, do as
follows:
Switch off the power switch,
, then
switch it on again so that the machine is in
start-up mode.
Press the
P8
button five times, then press
the
P4
button five times. You have to comple-
te these ten button presses within fifteen se-
conds.
Within three seconds of pressing the
P4
button for the fifth time you must then select
the type of water intake you want by pressing
the
P6
,
P7
or
P8
buttons.
P6
to use cold water intake only (C).
P8
to use mixed hot and cold water (E).
A letter C near the bottom right of the dis-
play shows that cold water is being used and
the letter E indicates mixed hot and cold.
CONNECTING TO THE DRAIN
Machine with drain pump
The machine is supplied with a drain hose al-
ready fitted and this should be connected to a
laundry sink, or the like, at a height of 600–900
mm above the floor.
The lower height (600 mm) is always prefera-
ble. Make sure the drain hose is not kinked.
Machine with drain valve
An outlet hose is supplied with the machine.
This must be connected to the outlet on the
m a c h i n e
and empty
into a floor
drain or
gutter drain.
NOTE!
The end of the outlet hose must be lower than
the lowest
point of the
outlet valve.