For Service Technician Use Only
DIAGNOSTICS (Cont.)
Low Profile Microwave Hood Combination
n
2-3
Diagnostics - Touch Panel
Touch Panel and ACU Test
The microwave hood combination is provided with a self-diagnostic routine that can be accessed through the touch keypad.
To initiate this routine:
1.
Plug in microwave oven or reconnect power, in idle mode,
close the door, turn off hood light and hood fan.
2.
Open and close door, then press CANCEL - CANCEL - START
within 3 seconds.
All LED/LCD segments will be lit to indicate the Test mode has
been entered.
3.
Open door. The model number will be displayed.
4.
Close door. All display segments will be lit.
5.
Press indicated keypad for correct display readout and beep.
NOTE:
If the Cancel button is pressed during this diagnostic
routine, you will exit the Test mode.
Key Tables for Test Mode
Key Name
The Upper Row Display
Function
Buzzer
Clock
value such as 0-200
NTC sensor check
1 beep
Start
ACU xx.xx.xx
ACU SW version check
1 beep
Start
UI:xx.xx.xx
UI SW version check
1 beep
Start
LT:xx
Left touch SW version check
1 beep
Start
RT:xx
Right touch SW version check
1 beep
Start
GEE:xx.xx.xx
GEE SW version check
1 beep
Hood Light
key 03 or 0009
-
1 beep
Hood Fan
key 04 or 0011
-
1 beep
Timer
key 05 or 0010
-
1 beep
Turntable On/Off
key 09
-
1 beep
Cook
value between 2000 and 9000
Humidity sensor check
1 beep
Power
-
-
1 beep
Reheat
key 24 or 0003
-
1 beep
Defrost
key 29 or 0005
-
1 beep
AccuPop
key 25
-
1 beep
Steam/Simmer
key 31
-
1 beep
Popcorn
0001
-
1 beep
Soften/Melt
0004
-
1 beep
Power/Time
0006
-
1 beep
0
key 10 or XXXX
GESE Version check
1 beep
1
P100
MW+Cavity light+Cooling Fan+Turntable On 1 beep
2
11 or CL or F9E3
Cavity Lamp+Cooling Fan ON
1 beep
3
HF_Mid LOW or FDE2
Turntable on
1 beep
4
HF_Mid HIGH
Hood Fan turn on (Mid High Speed)
1 beep
5
LCD off
Standby power check
1 beep
6
HL_HIGH
Hood Light turn on (high level)
1 beep
7
HL_LOW
Hood Light turn on (low level)
1 beep
8
HF_HIGH
Hood Fan turn on (High Speed)
1 beep
9
HF_LOW
Hood Fan turn on (LOW Speed)
1 beep
Cancel
: or xx:xx or Clock
Exit test mode to idle mode
1 beep