4-7
Freezer Components (continued)
Checking defrost Bimetal
Checking defrost Heater
Disconnect power to the refrigerator.
1. Slide the defrost bimetal off the coil.
2. Disconnect the wiring harness.
3. Disconnect the green chassis ground wire
attached to the evaporator heat shield.
4. Connect an Ohmmeter across the
Bimetal wires inserted into the wiring
harness connector. If the bimetal is
warm the meter should indicate an open
circuit. If the Bimetal is at normal freezer
temperature -5 to +5 degrees F, the
meter should measure less than 1 OHM
of resistance indicating a closed circuit.
1
2
3
4
Disconnect power to the refrigerator.
1. Disconnect the two black wires attached
to the defrost heater.
2. Connect an Ohmmeter across the heater.
In this example the resistance measured
is 31.6 OHMS.
note:
Refer to the tech sheet for the refrigera-
tor being tested for the resistance of the
heater.
2
electrical Shock Hazard
disconnect power before servicing.
replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
WARNING
Summary of Contents for GSF26C5EXS
Page 7: ...1 3 ...
Page 10: ...2 2 Installation Example Installation Instructions continued hex ...
Page 11: ...2 3 Installation Example continued Installation Instructions continued ...
Page 16: ...2 8 NOTES ...
Page 39: ...4 17 Freezer Components continued ...
Page 62: ...5 18 NOTES ...
Page 71: ...7 1 DIAGNOSTICS WIRING DIAGRAMS AND TROUBLESHOOTING ...
Page 72: ...7 2 Diagnostics Wiring Diagrams And Troubleshooting continued ...
Page 75: ...7 5 Diagnostics Wiring Diagrams And Troubleshooting continued ...
Page 77: ...7 7 Diagnostics Wiring Diagrams And Troubleshooting continued ...
Page 78: ...7 8 Diagnostics Wiring Diagrams And Troubleshooting continued ...
Page 80: ......