3-1
PRODUCT OPERATION
ELECTRONIC IGNITION SYSTEM
SPARK
MODULE
7
PRESSURE
REGULATOR
GAS INLET
AIR SHUTTER
GAS VALVE
IGNITOR SWITCH
VENTURI
BURNER
CONTROL
KNOB
GAS
MANIFOLD
SPARK
IGNITOR
BURNER CAP
TO SPARK
IGNITOR
SPARK
BURNER
BURNER FLAME
GAS FLOW
120 VAC
LINE VOLTAGE
GAS FLOW
HIGH VOLTAGE
LOW AMPERAGE
PULSES
OFF
LITE
4
9
8
10
2
5
6
1
3
SEALED BURNER
When a main burner control knob
q
is turned to the “lite” position, the gas valve
r
opens, and
gas flows through the pressure regulator
s
into the manifold
t
through the open valve. As gas
passes through the valve and its orifice, it is directed into the venturi
u
, where it mixes with
primary air to create the proper mixture necessary for combustion.
At the same time, line voltage is applied through the ignitor switch
v
, to the spark module
w
,
which produces high-voltage, low amperage pulses to all of the spark ignitors
x
. The pulses
cause a spark
y
to occur between the spark ignitor electrode, and the grounded burner cap
z
.
The gas and air mixture at the burner is ignited by the spark, and a flame is produced at each
of the top burner ports.
Refer to Figure 3-1 for the following sequence.
Figure 3-1
Summary of Contents for GLT3014G
Page 1: ...JOB AID Part No 4317256 WHIRLPOOL KITCHENAID BUILT IN GAS COOKTOPS ...
Page 8: ... viii NOTES ...
Page 10: ...1 2 WHIRLPOOL MODEL GAS COOKTOPS SCS3004G SCS3014G SCS3614G GLT3014G GLT3614G ...
Page 12: ...1 4 15 30 36 GAS GLASS COOKTOPS ...
Page 22: ...2 10 NOTES ...
Page 24: ...3 2 NOTES ...
Page 34: ...6 2 NOTES ...
Page 44: ...8 6 NOTES ...