INSTALLATION REQUIREMENTS

Tools and Parts

Tools Needed 

Gather the required tools and parts before starting installation. 
Read and follow the instructions provided with any tools listed 
here.

Parts Needed

Your freezer dealer has a kit available with a 

¹⁄₄

" (6.35 mm) 

saddle-type shutoff valve, a union, and copper tubing.

Or you can purchase a 

¹⁄₄

" (6.35 mm) copper tubing with 

shutoff valve and a 

¹⁄₄

" (6.35 mm) compression fitting 

(coupling).

Depending on water line connections, you may also need a 

¹⁄₄

(6.35 mm) nut and 

¹⁄₄

" (6.35 mm) ferrule.

Parts Supplied with Freezer

Remove the parts from the Ice Maker Adapter kit that was 
supplied with your freezer. Check to see that these parts are 
included.

Parts Supplied with Ice Maker Kit

Remove the parts from the ice maker kit. Check to see that all 
parts are included. Some of the included parts will not be used for 
this freezer.
IMPORTANT: Do not remove the tubing from the water valve. It 
has been factory installed and leak tested. Do not move the 
compression nut that connects the tubing to the valve or the valve 
may leak after you connect it to the water supply.

*Not used in two door freezer

Cordless drill 

¹⁄₄

" nut driver and drill bit

Flat-blade screwdriver

#2 Phillips screwdriver

⁷⁄₁₆

" and 

¹⁄₂

" open-end 

wrenches or two adjustable 
wrenches

Small 

³⁄₄

" round file

Tubing cutter

Scissors

Ruler

Level

Step stool (optional)

A. Long shutoff arm
B. Ice maker cover

C. Flat wire shelf

A

B

C

A. Ice maker
B. Ice bin* 

C. Water valve with tubing
D. Fill tube (short)*

E. Gasket*

F. Short extension tube*

G. Metal water tube insert

H. Long extension tube*

I. Ice maker clips (2)*

J. Tubing clips (2)*

K. Water valve tubing clamp

L.

¹⁄₂

" hex-head sheet metal screws (4)

M.

³⁄₄

" hex-head sheet metal screws (2)

N.

¹⁄₂

" hex-head machine screws (2)

A

B

D

F

E

H

C

I

J

G

K

L

N

M

Summary of Contents for EV209NBT - INSTALLATION 5-10

Page 1: ...ON 12 DÉPANNAGE 15 W10326826A You can be killed or seriously injured if you don t immediately You can be killed or seriously injured if you don t follow All safety messages will tell you what the potential hazard is tell you how to reduce the chance of injury and tell you what can happen if the instructions are not followed Your safety and the safety of others are very important We have provided m...

Page 2: ...at all parts are included Some of the included parts will not be used for this freezer IMPORTANT Do not remove the tubing from the water valve It has been factory installed and leak tested Do not move the compression nut that connects the tubing to the valve or the valve may leak after you connect it to the water supply Not used in two door freezer Cordless drill nut driver and drill bit Flat blad...

Page 3: ...ter SupplyConnection Connect to Water Line 1 Unplug freezer or disconnect power 2 Turn OFF main water supply Turn ON nearest faucet long enough to clear line of water 3 Locate a to 1 12 7 mm to 3 18 cm vertical cold water pipe near the freezer IMPORTANT Make sure it is a cold water pipe Horizontal pipe will work but drill on the top side of the pipe not the bottom This will help keep water away fr...

Page 4: ...s clear of all tape 9 Remove the ice maker connection cover 10 Pull the 4 wire harness out from behind the freezer s back cover as far as possible without forcing Hang it over the edge of the cutout 11 Reinstall the ice maker connection cover WARNING Electrical Shock Hazard Disconnect power before servicing Replace all parts and panels before operating Failure to do so can result in death or elect...

Page 5: ... Tubing Clips 1 Peel the backing from the adhesive strips on the tubing clips 2 Press the clips against the back of the freezer in the locations shown below Connect the Water Valve Tubing 1 Position the water valve tubing clamp with the round hole facing toward you and slide it over the end of the fill tube spout NOTE One of the flanges on the water valve tubing clamp is made for a threaded screw ...

Page 6: ...onnect the wiring harness to the wiring harness connector so that the locking arm snaps over the raised tab The connectors will fit together only one way 5 Partially install the two upper mounting screws into the ice maker cover Position the ice maker assembly onto the upper screws 6 Install the lower mounting screw Tighten all screws Do not overtighten 7 Ensure that the fill tube is fitted into t...

Page 7: ...wer the arm on the ice maker and close the freezer door NOTE Allow 24 hours to produce the first batch of ice Discard the first three batches of ice produced For more information see Ice Maker in the Use and Care Guide TROUBLESHOOTING Try the solutions suggested in the Use and Care Guide to avoid the cost of an unnecessary service call The ice maker is not producing ice or not enough ice Refer to ...

Page 8: ...8 Notes ...

Page 9: ...t les instructions Risque possible de décès ou de blessure grave si vous ne suivez pas les instructions Tous les messages de sécurité vous diront quel est le danger potentiel et vous disent comment réduire le risque de blessure et ce qui peut se produire en cas de non respect des instructions Votre sécurité et celle des autres est très importante Nous donnons de nombreux messages de sécurité impor...

Page 10: ...êt à étrier est conforme aux codes locaux de plomberie Ne pas employer de robinet d arrêt à étrier de 4 76 mm ou de type à percer ils réduisent le débit de l eau et sont plus susceptibles de causer une obstruction Pression de l eau Une alimentation en eau froide avec une pression entre 30 et 120 lb po 207 et 827 kPa est nécessaire pour faire fonctionner la machine à glaçons Pour des questions au s...

Page 11: ...ide d une perceuse sans fil percer un trou de 6 35 mm dans la canalisation d eau froide choisie 6 Fixer le robinet d arrêt sur la canalisation d eau froide avec la bride de tuyau Vérifier que l extrémité du raccord du robinet est bien engagée dans le trou de 6 35 mm percé dans la canalisation et que la rondelle d étanchéité se trouve sous la bride du tuyau 7 Serrer l écrou de serrage 8 Serrer unif...

Page 12: ...ment de la machine à glaçons 10 Tirer sur le faisceau de câblage à 4 fils de l arrière du congélateur autant que possible sans forcer Le faire pendre au dessus du bord de l ouverture découpée 11 Réinstaller le couvercle de raccordement de la machine à glaçons AVERTISSEMENT Risque de choc électrique Déconnecter la source de courant électrique avant l entretien Replacer pièces et panneaux avant de f...

Page 13: ...a protection des bandes adhésives situées sur les attaches du tuyau 2 Fixer les attaches à l arrière du congélateur aux emplacements indiqués ci dessous en appuyant dessus Raccordement du tuyau du robinet 1 Placer la bride du tuyau du robinet avec l anneau face à soi et l enfiler par dessus l extrémité du bec du tuyau de remplissage REMARQUE L un des rebords de la bride du tuyau du robinet est con...

Page 14: ... verrouillage s emboîte sur la languette en position élevée Les connecteurs ne peuvent être raccordés que d une seule façon 5 Placer et serrer partiellement les deux vis de montage supérieures dans le couvercle de la machine à glaçons Placer la machine à glaçons sur les vis supérieures 6 Installer la vis de montage inférieure Serrer toutes les vis Ne pas serrer excessivement 7 S assurer que le tuy...

Page 15: ... glaçons et fermer la porte du congélateur REMARQUE Prévoir un délai de 24 heures pour la production du premier lot de glaçons Jeter les trois premiers lots de glaçons produits Pour plus de renseignements voir Machine à glaçons dans le Guide d utilisation et d entretien DÉPANNAGE Essayer les solutions suggérées dans le Guide d utilisation et d entretien afin d éviter le coût d une visite de servic...

Page 16: ...W10326826A 2010 All rights reserved Tous droits réservés 5 10 Printed in U S A Imprimé aux É U ...

Reviews: