18
CABINET
Fig. 7
4. Rotate the access cover on the washer top clockwise to expose the hose assemblies under-
neath.
(Fig. 6)
5. Disconnect the bleach dispenser venturi hoses and the detergent and fabric softener inlet
hoses as indicated in
Figure 6
.
6. Pull the inner basket forward, to avoid damage to the tub ring, splash guard and shield. Re-
move
the cabinet by tilting it forward and pulling it away from the washer.
(Fig. 7)
BLEACH DISPENSER
VENTURI HOSE
DETERGENT
DISPENSER
INLET HOSE
FABRIC SOFTENER
DISPENSER
OUTLET HOSE
Fig. 6
BLEACH DISPENSER
VENTURI HOSES
VENTURI
ACCESSING COMPONENTS IN THE WASHER CABINET
Components inside the washer cabinet can be accessed by completely removing
the outer cabinet as one unit. Refer to
Figure 5
for the following instructions.
1. Remove the console mounting screws and
tilt the console into the service position.
2. Unplug the lid switch harness connector
from the receptacle in the washer top.
3. Remove the cabinet mounting clips
by placing the flat blade of a screwdriver
in the clip as shown in
Figure 5, Inset 1
.
INSET 1
CLIP
CLIP
Fig. 5