9
Water Temp
The WATER TEMP keypad provides for selection of different wash and rinse combinations. Water fill
temperatures can be either HOT (hot water valve only), WARM (both the hot and cold water valves) or
COLD (cold water valve only). Fills during rinses may be COLD until the final rinse/spin interval.
The WATER TEMP can be changed at any time during the wash cycle. The action takes place during
a water fill, or the next water fill. Changes late in the cycle are allowed, but may not be acted upon.
SELECTED CYCLE
Whitest Whites
Heavy Duty
Normal
Jeans/Darks
Bulky Items
Quick Wash
Delicate Casual
Wool
Hand Wash
DEFAULT WATER TEMP
Hot/Cold (no ATC)
Warm/Cold (with ATC)
Warm/Cold (with ATC)
Warm/Cold (with ATC)
Warm/Cold (with ATC)
Warm/Cold (with ATC)
Warm/Cold (with ATC)
Cold/Cold (with ATC)
Cold/Cold (with ATC)
Assured Water Temp
The Assured Water Temp LED (if available) lights up whenever the temperature selection is an auto-
controlled temp. There are three auto-controlled temperature selections:
•
WARM (100°F)/WARM (75°F)
•
WARM (100°F)/COLD (“TAP” unregulated)
•
COLD (75°F)/COLD (“TAP” unregulated)
There is another WATER TEMP selection that is not auto-controlled (TAP COLD/COLD). Auto temp
control uses the thermistor input as feedback to regulate the hot and cold water valves to achieve the
desired temperature.
ATC Thresholds
Median
75° F
100° F
High Trip
~80° F
46.3K
Ω
~109.9° F
24.2K
Ω
Low Trip
~72° F
56.3K
Ω
~89.9° F
37.6K
Ω
AUTO CONTROLLED
Cold Wash/Warm Rinse
Warm Wash
NOTE: ATC controls COLD WASH, WARM RINSE and WARM WASH functions. COLD RINSE is not ATC controlled.
Summary of Contents for CALYPSO WashMotion GVW9959K-0
Page 1: ......
Page 64: ...60 NOTES ...
Page 65: ...61 SECTION FIVE TECH TIPS WIRING DIAGRAM Fig 5 1 ...
Page 68: ...CO RPO RATIO N ...