5-2
DRAIN PUMP
Refer to page 4-13 for the procedure for ac-
cessing the drain pump.
1. Unplug washer or disconnect power.
2. Disconnect the wire connector from the
drain pump terminals.
3. Set the ohmmeter to the R x 1 scale.
4. Touch the ohmmeter test leads to each
of the drain pump terminals. The meter
should indicate between 10.5 and 14
Ω
.
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
WARNING
Terminals
RECIRCULATION PUMP
Refer to page 4-13 for the procedure for ac-
cessing the recirculation pump.
1. Unplug washer or disconnect power.
2. Disconnect the wire connector from the
recirculation pump terminals.
3. Set the ohmmeter to the R x 1 scale.
4. Touch the ohmmeter test leads to each of
the recirculation pump terminals. The me-
ter should indicate between 30 and 38
Ω
.
Terminals
Summary of Contents for Cabrio WTW6200S
Page 4: ... iv NOTES ...
Page 20: ...2 10 NOTES ...
Page 40: ...3 20 NOTES ...
Page 60: ...4 20 NOTES ...
Page 82: ...7 2 NOTES ...
Page 84: ......