background image

6

                                                                                       

COMPONENTS   

Ref

 

Qty

 

Components

 

1

 

1pcs 

Grease filter

 

1pcs 

Charcoal filter 

3

 

1pcs

 

Hood body

 

4

 

2

pcs

   

steel bolt

 

5

 

3

pcs

   

Cross self-drill bolt

 

6

 

1

pcs

 

 

Exhaust 

 

7

 

1

pcs

 

 

Exterior chimney

 

8

 

1

pcs

 

 

Inner chimney

 

9

 

2

pcs

 

 

Cross discal thread bolt

 

10

 

1

pcs

 

 

Fixing frame

 

11

 

2

pcs

 

 

Cross discal bolt-big head

 

12

 

2

pcs

 

 

Flat rubber band

 

13

 

2

pcs

 

 

Plastic distensible sleeve

 

 

Ref 

Qty 

Documentations 

14 

1pc 

Instruction Manual 

 

INSTALLATION & USE 

 

Note 1: Carefully remove the protective film from chimney and front panel 

prior to final installation.   

Note 2:    At least two people will be required to mount the hood. 

 

FIXING TO THE WALL

 

  Fig.1 

1. Drill the holes according to the distances indicated (Fig.2).   

2. Fix the appliance to the wall and align it in horizontal position to 

Summary of Contents for AKR912CIXM

Page 1: ...INSTRUCTION MANUAL T Box Hood AKR912CIXM ...

Page 2: ...ight Power 2x1 5W Motor Power 310W Total Power 313W Maximum suction 1300m3 hr Diameter of Exhaust Pipe 170mm Product Dimension mm AKR912IXM L 980 x W 680 x H 560 Net Weight AKR912IXM 24kg Gross Weight AKR912IXM 29kg RECOMMENDATIONS AND SUGGESTIONS INSTALLATION The manufacturer will not be held liable for any damages resulting from incorrect or improper installation Please read this instruction man...

Page 3: ...hen must have an opening directly with the open air in order to guarantee the entry of clean air The minimum distance is 750mm from the cooker hood to a gas hob and is 650mm to an electric hob If the installation instructions for gas electric hobs specify a greater distance the same must be taken into account NOTICE Considering excessive weight two or more people are required to install or move th...

Page 4: ...ppliances may be a danger hazard Do not check the status of the filters while the cooker hood is operating Do not touch the light bulbs during immediately after appliance use Do not disconnect the appliance with wet hands Avoid naked flame as it may damage the filters and a fire hazard Constantly check a frying food to avoid that the overheated oil may become a fire hazard Disconnect the electrica...

Page 5: ...quate ventilation of the room when the range hood is used at the same time as appliances burning gas or other fuels There is a fire risk if cleaning is not carried out in accordance with instructions Do not leave bare flames under the range hood The discharge air must not be discharged into a flue which is used for exhausting fumes from appliances burning gas or other fuels CHARACTERISTICS DIMENSI...

Page 6: ...5 ...

Page 7: ... discal bolt big head 12 2pcs Flat rubber band 13 2pcs Plastic distensible sleeve Ref Qty Documentations 14 1pc Instruction Manual INSTALLATION USE Note 1 Carefully remove the protective film from chimney and front panel prior to final installation Note 2 At least two people will be required to mount the hood FIXING TO THE WALL Fig 1 1 Drill the holes according to the distances indicated Fig 2 2 F...

Page 8: ...rrange the electrical power supply within the dimensions of the chimney If your appliance is to be installed in the ducting version or in the version with external motor prepare the air exhaust opening 2 Adjust the width of the support bracket of the exterior chimney Fig 3 Then fix it to the ceiling using the screws A Fig 2 make sure that it is in line with your hood and respecting the distance fr...

Page 9: ...where the ductwork will run between the hood and the outside 2 A straight short duct run will allow the hood to perform most efficiently 3 Long duct runs elbows and transitions will reduce the performance of the hood Use as few of them as possible Larger ducting may be required for best performance with longer duct runs 4 Attach an adequate length of φ160mm round duct to the air outlet adapter Let...

Page 10: ...ical power at service entrance before wiring If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard Do not use the plug and an extension cord other than the ones initially supplied with the hood The earthing of this hood is compulsory Do not remove ground prong of the plug OPERATION OF CONTROLS Commands patt...

Page 11: ...will run for 5 minutes then automatic switch off Minimum cut off time for timer is 5 minutes and maximum cut off time for timer is 50 minutes MAINTENANCE Switch off or unplug the appliance from the mains supply before carrying out any maintenance work GREASE FILTER The grease filters should be cleaned frequently every two months of operation or more frequently for heavy use Use a warm detergent so...

Page 12: ...o of the easiest materials to keep clean Occasional care will help preserve its fine appearance Cleaning tips Hot water with soap or detergent is all that is usually needed Follow all cleaning by rinsing with clear water Wipe dry with a clean soft cloth to avoid water marks For discolorations or deposits that persist use a non scratching household cleanser or stainless steel polishing powder with ...

Page 13: ...power supply and refer to the guide below to determine the problem S No Status Reasons Solutions Power supply not connected Check if the power cord is properly connected or not 1 Lamp doesn t work Lamp is damaged Call consumer service for support Filter not properly fitted Remove and refit the filters in its place 2 Hood gives out loud noise Hood is not installed properly Call consumer service for...

Page 14: ...13 ...

Reviews: