![Whirlpool AGB 356/WP Instructions For Installation, Use And Maintenance Manual Download Page 10](http://html.mh-extra.com/html/whirlpool/agb-356-wp/agb-356-wp_instructions-for-installation-use-and-maintenance-manual_432252010.webp)
3 - TECHNICAL DATA
Primary air distance “A”
Methane gas G20
Liquid gas G30/G31
TABLE 1
Model
Category
Construction type
Air necessary for combustion
Nominal thermal power
Minimum thermal power
Overall thermal power (gas)
Connection pressure
Methane gas 2H
Liquid gas 3+
Gas connection values
Methane gas 2H
Liquid gas 3+
Nozzles Ø 1/100 mm
Main burner
G20
G30/G31
(HuB = 9.45 kWh/m
3
) in m
3
/h
(HuB = 12.87 kWh/kg) in kg/h
Nominal thermal power
Minimal thermal capacity
Nominal thermal power
Minimal thermal capacity
G20
G30/31
20 mbar
28/37 mbar
II2H3+
A
m
3
/h
kW
kW
No. of nozzles, pilot burner
G20
G30/G31
3
Open
Gas oven
MAXI
24
12.0
-
270
-
170
-
36
19
Electrical data
Electric oven power:
GN 2/1 -
5.9
kW
GN 1/1 -
2.5
kW
Voltage:
V 400 3N 50 Hz / 230 3 50 Hz
230 50 Hz
No. of cables per section:
5 x 2.5 mm
2
/ 4 x 2.5 mm
2
3 x 1.5 mm
2
7
Open
X
Ø 100
8
4.0
1.2
145
Adjustable
100
45
27
19
9
Open
Y
Ø 120
12
6.0
1.8
185
Adjustable
125
75
27
19
Open
Open
Gas oven
GN 1/1
7.5
3.6
0.75
155
Adjustable
100
48
-
-
12
18
Gas oven
GN 2/1
16
7.8
-
215
-
140
-
35
20
0.423
0.313
0.635
0.470
0.381
0.282
0.825
0.611
1.270
0.939
Hour consumption
G20
m
3
/h
G25
m
3
/h
G30/G31
kg/h
Fix
Fix
Solid
Gas range
16
8.0
5.5
0.847
0.626
200
Adjustable
140
60
35
25
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
AGB 499/WP
AGB 483 - 493 - 486 - 500/WP
AGB 491/WP
AGB 495/WP
AGB 489/WP
AGB 356/WP
AGB 492/WP
AGB 484/WP
AGB 494/WP
AGB 485/WP
AGB 490/WP
AGB 488/WP
AGS 775/WP
ADN 021/WP
ADN 019/WP
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
10.0
20.0
26.0
28.0
23.8
12.0
23.6
27.8
31.6
35.8
40.0
16.0
33.8
20.8
29.2
1,06
2,12
2,75
2,96
2,52
1,27
2,50
2,94
3,34
3,79
4,23
1,69
3,58
2,20
3,10
0,78
1,56
2,03
2,19
1,86
0,94
1,85
2,18
2,47
2,80
3,13
1,25
2,65
1,63
2,28
064_03
- GAS KITCHENS
10
· 26
07/2007