Before commissioning the appliance 

Before commissioning the appliance, remove the pro-
tective wrapping. 
Thoroughly clean the work-surface and the outside of
the appliance using lukewarm water and detergent. 
With a damp cloth eliminate all traces of the rust-proo-
fing applied in the workshop then dry with a clean cloth.

Start-up 

Before starting the appliance up, check that its specifi-
cations (category and type of gas used) match those of
the family and group of the gas available locally. 
If not, adapt the appliance to the gas family or group re-
quired (see paragraph “Running the appliance on other
types of gas” page 11). 
To start the appliance up, see the instructions for regu-
lar use. 

Testing the power rating

Use the specific nozzles for the nominal capacity on the
appliance. 
Capacity can be of two types: 

- nominal, as given on the data plate; 

- minimum. 

These nozzles are shown in table 1 in the assembly in-
structions. 
The following are the operating pressure tolerances to ob-
tain the nominal power according to the agreed nozzles:

- from 15 to 22.5 mbar for gases of the second family 

- from 25 to 45 mbar for gases of the third family 

(propane).

The appliance will not work outside the above pressure
threshholds. 
To adjust the capacity to its minimum value, use the da-
ta in tables 1 (Gas Flow Regulation table). 
If you wish to check the nominal capacity further, you
may do so using a gas meter according to the so-called
”volumetric method”. 
It is normally enough, however, simply to check that the
nozzles are functioning correctly. 

Checking input pressure (Fig. 3) 

Input pressure should be measured using a gauge (e.g.
a gooseneck pipe, min. resolution 0.1 mbar). 
Remove screw (22) from the pressure socket and con-
nect it to the tube on the gauge; after measuring, the
screw should be retightened absolutely airtight (22).

Checking power rating using the 
volumetric method

Using a gas meter and a chronometer, you can read

the volume of gas output per time unit. 
The correct volume will be the value of “E” expressed in
litres per hour (It/hr) or litres per minute (It/min). 
The following formula is used to calculate the value of
“E”: 

Capacity should only be measured when the appliance
is at a standstill. 
The heat value can be obtained from your local Gas
Board. 
To obtain the nominal and minimum capacities in rela-
tion to the nominal pressure, consult table (1- Gas Flow
Setting). 

WARNING

It is not possible to adjust nominal capacity in ad-
vance. 

Checking power rating when using
LP gas

Check that the type of nozzles used match table 1 spe-
cifications. 
Check that the output pressure regulator installed colla-
terally to the plant conforms to the specifications laid
down in paragraph "Testing the power rating" (see data
plate and measure the pressure). 

Capacity

Heat value

E =

COMMISSIONING THE APPLIANCE

4

22

6

1

5

3

2

3

Summary of Contents for AGB 055/WP

Page 1: ...013_03 Installation operating and maintenance instructions 10 2005 GAS PASTA COOKER AGB 448 WP AGB 450 WP AGB 527 WP AGB 529 WP AGB 055 WP AGB 057 WP ...

Page 2: ...ctions 11 Note for the installer 11 Running the appliance on other types of gas 11 Replacing the main burner nozzle 11 Pilot burner nozzle 11 Adjusting the low flame 11 Maintenance page 11 Replacing parts 12 Ignition plung 12 Gas tap 12 Thermocouple 12 Using the appliance 13 First time use of the appliance 13 Ignition 13 Turning the pilot burner on 13 Turning the main burner on and adjusting the t...

Page 3: ...tap Inlet tap Gas control knob Piezo electric lighter Water outlet Water inlet Gas connection A B C D E F G C B D A G 21 21 220 F E 220 410 310 G 100 100 F E 250 AGB 448 WP weight approx 100 kg G 21 21 220 F E 220 410 310 G 100 100 F E 250 C B D A ...

Page 4: ...F G C B D A AGB 450 WP G 21 21 220 F E 220 410 310 G 100 100 F E 250 A C D C B D weight approx 112 kg AGB 055 WP weight approx 70 kg Drainage tap Inlet tap Gas control knob Piezo electric lighter Water outlet Water inlet Gas connection A B C D E F G ...

Page 5: ... pasta cooker 5 Dimensions A C D C B D 900 C B D A 800 900 A F G Drainage tap Inlet tap Gas control knob Piezo electric lighter Water outlet Water inlet Gas connection A B C D E F G AGB 057 WP weight approx 96 kg ...

Page 6: ...20 310 250 G G 21 21 220 285 100 100 F F E E 220 310 250 D B C A G G 21 21 220 285 100 100 F F E E 220 310 250 A AGB 529 WP D B C D B C weight approx 96 kg weight approx 112 kg Drainage tap Inlet tap Gas control knob Piezo electric lighter Water outlet Water inlet Gas connection A B C D E F G ...

Page 7: ... LV LT NO MT CY IS HU CY MOD MOD ART N N Qn kW m3 h MADE IN ITALY Predisposto a gas Gas preset Prevu pour gaz Eingestelt für Gas Preparado para gas Geschuckt voor V AC kW Hz THE APPLIANCE MUST BE CONNECTED IN COMPLIANCE WITH THE LAWS IN FORCE AND INSTALLED IN A WELL VENTILATED ROOM READ THE INSTRUCTION MANUALS BEFORE INSTALLING AND USING THE APPLIANCE THE APPLIANCE MUST BE INSTALLED BY QUALIFIED P...

Page 8: ...Wh m3 m3 h HuB 12 87 kWh kg kg h Nominal capacity Low flame Nominal capacity Low flame G20 G30 31 20 mbar 28 37 mbar II2H3 A m3 h kW kW No of nozzles pilot burner G20 G30 G31 15 4 245 adjustable 160 100 adjustable 20 21 10 5 4 1 15 4 2 x 245 adjustable 2 x 160 2 x 100 adjustable 20 42 10 5x2 21 0 4 1x2 8 2 22 20 2 x 230 adjustable 2 x 150 2 x 100 adjustable 20 36 9x2 18 0 3 8x2 7 6 22 20 230 adjus...

Page 9: ...nical re quisites should be adhered to relevant national legislation local building and fire safety regulations worksheet Technical rules for installing gas worksheet Technical rules for LP gas worksheet Gas installations in industrial kitchens industrial injury legislation local Gas Board regulations current CEI regulations INSTALLATION Assembly installation and maintenance i e assembly connectin...

Page 10: ...as Flow Regulation table If you wish to check the nominal capacity further you may do so using a gas meter according to the so called volumetric method It is normally enough however simply to check that the nozzles are functioning correctly Checking input pressure Fig 3 Input pressure should be measured using a gauge e g a gooseneck pipe min resolution 0 1 mbar Remove screw 22 from the pressure so...

Page 11: ...as been transformed or adapted recheck its functions as described in paragraph Checking the functions Replacing the main burner nozzle To change nozzle 30 open the doors Unscrew the nozzle from the nozzle holder using a 12 spanner repla ce with a new nozzle see TECHNICAL DATA table If necessary to make changing the nozzle easier loo sen screws 39 to remove the air adjustment sleeve Pilot burner ad...

Page 12: ...ion lead loosen the lock nut and insert a new plug Gas tap Fig 3 Loosen the gas piping and thermocouple hoses then loosen the screws fixing the gas supply to the gas ramp and insert a new tap Thermocouple Figs 2 3 Loosen the screws fixing the thermocouple 38 to the gas 6 tap and the pilot burner 34 insert the new part After replacing the parts fit the control panel and its parts back in the right ...

Page 13: ...ob to the right until it is on high or else continue until it reaches low the heating capacity must be set between these two positions TURNING THE APPLIANCE OFF Turning the appliance off during normal operation To turn the main burner off only simply turn the knob to this way only the pilot burner will stay on To turn the appliance off completely turn the knob to this will turn the pilot burner of...

Page 14: ...de of fibrous synthetic material rubbing in the direction of the satin finish Rinse and dry thoroughly Never use wire wool for cleaning stainless steel or leave it in contact with the steel as very small ferrous deposits could remain on the surface and cause the formation of ru st by contamination Precautions during use Sauces and condiments all the stainless steel containers used for notoriously ...

Page 15: ...AL PRODUCT IMPRO VEMENT THE MANUFACTURER RESERVES THE RIGHT TO MAKE ANY CHANGES DEEMED NECESSARY THE MANUFACTURER CANNOT BE HELD RESPONSI BLE IF THE INSTRUCTIONS CONTAINED IN THIS MA NUAL ARE NOT OBSERVED WHIRLPOOL EUROPE srl V le Guido Borghi 27 I 21025 Comerio VA ...