INSTALLATION REQUIREMENTS

Tools and Parts

Gather the required tools and parts before starting installation. 
Read and follow the instructions provided with any tools listed 
here.

Tools needed

Parts supplied

Check that all parts are included in parts package.

Location Requirements

IMPORTANT: Observe all governing codes and ordinances.

Check the location where air conditioner will be installed. Proper 
installation is your responsibility. Make sure you have everything 
necessary for correct installation.

The location should provide:

Grounded electrical outlet within 4 ft (122 cm) of where the 
power cord exits the air conditioner. 

NOTE: Do not use an extension cord.

Free movement of air in room to be cooled.

A large enough opening for the air conditioner. Installation 
parts are supplied for double-hung windows.

Adequate wall support for weight of air conditioner. Air 
conditioner weighs 81 lbs (36.7 kg) to 91 lbs (41.28 kg).

NOTE: Cabinet louvers must not be obstructed. Air must be able 
to pass freely through the cabinet louvers.

Window installation

Window opening measurements:

26" (66 cm) minimum to 38" (96.5 cm) maximum opening 
width.

15

¹⁄₂

" (39.4 cm) minimum opening height.

IMPORTANT SAFETY INSTRUCTIONS

WARNING:

 

To reduce the risk of fire, electrical shock or injury when using your air conditioner, follow these basic precautions:

  

SAVE THESE INSTRUCTIONS

Unplug air conditioner before servicing.

Use two or more people to move and install air conditioner.

Plug into a grounded 3 prong outlet.

Do not remove ground prong.

Do not use an adapter.

Do not use an extension cord.

Flat-blade and Phillips 
screwdrivers

Level

Scissors

Tape measure

Drill and 

³⁄₃₂

" or smaller bit

A. Window-lock bracket
B. Foam seal 

C. #8 x 

³⁄₈

" pan-head screws (6)

D. #10 x 

³⁄₈

" pan-head screws (3)

E. #8 x 

³⁄₄

" round-head 

screws (3)

F. Side curtains (2)

G. Top channel

A

B

C

D

E

F

G

A. Cabinet louvers

A. 26" (66 cm) minimum, 38" (96.5 cm) maximum
B. 15

¹⁄₂

" (39.4 cm) minimum

A

A

B

Summary of Contents for ACM122XR0

Page 1: ...formance parts accessories or service call 1 800 253 1301 ACONDICIONADOR DE AIRE ManualdeUsoyCuidado Si tiene preguntas respecto a las características funcionamiento rendimiento partes accesorios o servicio técnico llame al 1 800 253 1301 Table of Contents Índice 2 1188054A ...

Page 2: ...USAR SU ACONDICIONADOR DE AIRE 16 Cómo poner en marcha su acondicionador de aire 16 Cómo cambiar la dirección del aire 16 Sonidos normales 17 CUIDADO DE SU ACONDICIONADOR DE AIRE 17 Limpieza del filtro de aire 17 Limpieza del panel delantero 17 Reparación de la pintura dañada 17 Mantenimiento anual 17 SOLUCIÓN DE PROBLEMAS 17 AYUDA O SERVICIO TÉCNICO 19 Accesorios 19 AIR CONDITIONER SAFETY You can...

Page 3: ...of air conditioner Air conditioner weighs 81 lbs 36 7 kg to 91 lbs 41 28 kg NOTE Cabinet louvers must not be obstructed Air must be able to pass freely through the cabinet louvers Window installation Window opening measurements 26 66 cm minimum to 38 96 5 cm maximum opening width 15 39 4 cm minimum opening height IMPORTANT SAFETY INSTRUCTIONS WARNING To reduce the risk of fire electrical shock or ...

Page 4: ...eakage current If the cord is crushed the electronics detect leakage current and power will be disconnected in a fraction of a second To test your power supply cord 1 Plug power supply cord into a grounded 3 prong outlet 2 Press RESET 3 Press TEST listen for click Reset button will trip and pop out 4 Press and release RESET listen for click Reset button will latch and remain in The power supply co...

Page 5: ... screws 5 Insert top and then bottom of right hand curtain housing in top and bottom curtain guides on air conditioner Back View Bottom View 6 Extend right hand curtain outward so you may insert the first screw through the middle hole of the curtain Using 8 x pan head screw screw curtain to middle hole in air conditioner cabinet NOTE This screw is required to correctly attach curtain top to bottom...

Page 6: ...utside 3 Pull left hand curtain out until it fits into the window channel Repeat with right hand curtain Front View 4 Insert one of the 8 x round head screws through left hand curtain and into the window channel or through alternate hole at the top of the curtain and into the window sash to fasten the curtain to the window Top View 5 Repeat for right hand curtain CompleteInstallation 1 Insert foam...

Page 7: ...s cooling The Exhaust control set to OPEN position allows you to draw stale or smoky air from the room Open to exhaust room air to the outside Closed to circulate room air NOTE The Exhaust control will function only when the Fan is operating Fan Set the Fan control to the desired setting When the air conditioner is operating at Low Cool High Cool or Turbo Cool the fan circulates air continuously T...

Page 8: ... for best cooling and operating efficiency Check the filter every 2 weeks to see whether it needs cleaning NOTE Do not operate the air conditioner without the filter in place 1 Turn off air conditioner 2 Using indents in top of filter door pull door down Filter door is not removable 3 Slide air filter up and out to remove from the filter door 4 Use a vacuum cleaner to clean air filter If air filte...

Page 9: ...t of cold air you may be accustomed to from older units but this is not an indication of lesser cooling capacity or efficiency Refer to the efficiency rating EER and capacity rating in BTU hr marked on the air conditioner The air conditioner is in a heavily occupied room or heat producing appliances are in use in the room Use exhaust vent fans while cooking or bathing and try not to use heat produ...

Page 10: ...553 Benson Road Benton Harbor MI 49022 2692 Please include a daytime phone number in your correspondence Please record your model s information Whenever you call to request service on your appliance you need to know your complete model number and serial number You can find this information on the model and serial number label See Electrical Requirements for model and serial number location Please ...

Page 11: ...ionar la muerte o una y de la palabra PELIGRO o ADVERTENCIA Estas palabras significan PELIGRO ADVERTENCIA a usted y a los demás Lea y obedezca siempre todos los mensajes de seguridad Todos los mensajes de seguridad irán a continuación del símbolo de advertencia de seguridad puede morir lesión INSTRUCCIONES IMPORTANTES DE SEGURIDAD ADVERTENCIA Para reducir el riesgo de incendio choque eléctrico o l...

Page 12: ...fe en el cable de alimentación eléctrica Método recomendado para la puesta a tierra Este acondicionador de aire debe ser puesto a tierra Este acondicionador de aire está equipado con un cable de suministro de energía provisto de un enchufe con tres terminales Para reducir a un mínimo el peligro de posibles choques eléctricos el cable debe ser enchufado en un contacto apropiado de pared de tres ter...

Page 13: ...de energía dañado debe ser reemplazado por un nuevo cable de suministro de energía obtenido del fabricante del producto y no debe ser reparado El cable de suministro de energíano contiene piezas que pueda arreglar el usuario Todos los reclamos de desempeño y la garantía quedarán anulados si se abre el estuche resistente a alteraciones INSTRUCCIONES DE INSTALACIÓN Desempaqueelacondicionadorde aire ...

Page 14: ...le la cortina a los orificios superior e inferior en el gabinete del acondicionador de aire NOTA Algunas cortinas pueden tener dos ranuras en cada extremo Usted podrá ver un orificio de montaje a través de la ranura correcta 8 Deslice el alojamiento de la cortina en las guías lo más lejos posible 9 Repita los pasos anteriores para la cortina izquierda Colocacióndelacondicionadorde aire Trate el ac...

Page 15: ...cio en el soporte y en el marco de la ventana 4 Fije el soporte de seguridad de la ventana al marco de la ventana con un tornillo de cabeza redonda 8 x para asegurar la ventana en su lugar 5 Conecte a un contacto de pared de conexión a tierra de 3 terminales 6 Presione RESET Reposición sobre el cable de suministro de energía A Cortina izquierda B Canal de la ventana A Cortina izquierda B Canal de ...

Page 16: ...tá funcionando Fan Ventilación Ponga el control de ventilación en la posición que desee Cuando el acondicionador de aire está funcionando a temperaturas Low Cool Poco fría High Cool Muy fría o Turbo Cool Máximo nivel de fría el ventilador hace circular el aire continuamente Turbo Cool para enfriamiento máximo High Cool para enfriamiento normal Low Cool para dormir cómodo Fan Only Sólo ventilación ...

Page 17: ...o hacia abajo en la puerta del filtro Cierre la puerta del filtro Limpiezadelpaneldelantero 1 Apague el acondicionador de aire 2 Quite el filtro de aire y límpielo por separado Vea Limpieza del filtro de aire 3 Limpie el panel delantero con un paño suave y húmedo 4 Seque el panel delantero al aire completamente Reparacióndelapinturadañada Revise una o dos veces al año si hay daños en la pintura Es...

Page 18: ...s que generan calor durante las horas más calurosas del día Podría necesitar un acondicionador de aire con más capacidad dependiendo del tamaño de la habitación que se desea enfriar El acondicionador de aire se enciende y se apaga demasiado o no enfría la habitación El control de FAN Ventilación está puesto en Power Saver Ahorro de energía en algunos modelos Utilice el modo de Ahorro de energía ún...

Page 19: ... 2692 Por favor incluya en su correspondencia un número de teléfono en el que se le pueda localizar durante el día Por favor anote la información sobre su modelo Siempre que llame para solicitar servicio del aparato necesitará saber el número del modelo y el número de serie completos Esta información la encuentra en la placa de número del modelo y número de serie Vea la ubicación del número del mo...

Page 20: ...1188054A 2005 All rights reserved Todos los derechos reservados 3 05 Printed in U S A Impreso en EE UU ...