12
9. Remove the two (2) hex head screws se-
curing the divider wall to the base plate of
the air conditioner.
(Fig. 3-15)
10. Remove the two (2) hex head screws se-
curing the condenser shroud to the base
plate of the air conditioner.
(Fig. 3-15)
11. Remove the two (2) nuts securing the fan
motor mounting bracket to the bolts on the
base plate of the air conditioner.
(Fig.3-15)
12. Confirm that the capacitor is discharged.
13. Remove nut and washer securing the com-
pressor terminals cover to the compressor.
(Fig. 3-16)
14. Disconnect the wiring harness connectors
from the compressor terminals.
15. The entire fan motor assembly, including the
fan motor, wiring harness, evaporator and
condenser fan blades,motor mounting
bracket and the unit support bracket can now
be lifted from the air conditioner. The ca-
pacitor will remain attached to the unit sup-
port bracket.
(Fig. 3-17)
When replacing the screen surrounding
the component compartment:
• Be sure the screen fits into the three (3) tabs
on each side of the divider wall.
• Be sure the screen seats flat on the base
plate of the air conditioner.
Failure to do so will result in damage to
the screen, undesirable noises during
operation and customer complaints.
!
NOTE
1 of 2
Screws
Securing
Divider Wall
to Base Plate
1 of 2
Screws
Securing
Condenser Shroud
to Base Plate
1 of 2
Nuts Securing
Motor Bracket
to Base Plate
Fig. 3-15
Fig. 3-16
Fig. 3-17
13
When replacing the fan motor assembly:
• Be sure the fan motor mounting bracket is
properly located so that the base plate bolts
protrude through the holes in the motor
mounting bracket.
Failure to do so will result in damage to
the air conditioner, undesirable noises
during operation and customer com-
plaints.
!
NOTE
Base Plate Bolt
protruding through Hole in
Fan Motor Mounting Bracket