A sturdy floor to support the washer/dryer weight (washer/
dryer, water and load) of 500 lbs (226.8 kg).

A level floor with a maximum slope of 1" (2.5 cm) under entire 
washer/dryer. Clothes may not tumble properly and automatic 
sensor cycles may not operate correctly if washer/dryer is not 
level. Installing on carpet is not recommended.

A water heater set to deliver 120°F (49°C) water to the washer.

Hot and cold water faucets located within 4 ft (1.2 m) of the 
hot and cold water fill valves, and water pressure of 5-100 psi 
(34.5-689.6 kPa).

The washer/dryer must not be installed or stored in an area where 
it will be exposed to water and/or weather.
Do not operate your washer in temperatures at or below 32ºF 
(0ºC). Some water can remain in the washer and can cause 
damage in low temperatures. See “Washer/Dryer Care” in the 
“Washer/Dryer User Instructions” for winterizing information.
Do not operate your dryer at temperatures below 45°F (7°C). At 
lower temperatures, the dryer might not shut off at the end of an 
automatic cycle. This can result in longer drying times.
Check code requirements. Some codes limit, or do not permit, 
installation of the washer/dryer in garages, closets, mobile homes, 
or sleeping quarters. Contact your local building inspector.

Installation Clearances

The location must be large enough to allow the dryer door to open 
fully.

Washer/Dryer Dimensions

*Most installations require a minimum 5½" (14 cm) clearance 

behind the dryer for the exhaust vent with elbow. See “Venting 
Requirements.”

Minimum installation spacing for recessed area or closet 
installation

The following dimensions shown are for the minimum spacings 
allowed.

Additional spacing should be considered for ease of 
installation and servicing.

Additional clearances might be required for wall, door and 
floor moldings.

Additional spacing of 1" (2.5 cm) on all sides of the washer/
dryer is recommended to reduce noise transfer.

For closet installation, with a door, minimum ventilation 
openings in the top and bottom of the door are required. 
Louvered doors with equivalent ventilation openings are 
acceptable.

Rear clearance may be 0" when house exhaust system is lined 
up directly with dryer exhaust.

Mobile Home - Additional Installation Requirements

This washer/dryer is suitable for mobile home installations. 
The installation must conform to the Manufactured Home 
Construction and Safety Standard, Title 24 CFR, Part 3280 
(formerly the Federal Standard for Mobile Home Construction and 
Safety, Title 24, HUD Part 280).
Mobile home installations require:

Metal exhaust system hardware which is available for 
purchase from your dealer.

Special provisions must be made in mobile homes to 
introduce outside air into the dryer. The opening (such as a 
nearby window) should be at least twice as large as the dryer 
exhaust opening.

15 

³⁄₈

"

(39.05 cm)

71 ¾"

(182.25 cm)

*27 ¼"

(69.22 cm)

23 

⁷⁄₈

"

(60.64 cm)

32 

¹⁄₈

"

(81.6 cm)

A. Recessed area
B. Side view - closet or confined area

C. Closet door with vents

0"

(0 cm)

      

0"

(0 cm)

A

B

C

3" (7.6 cm)

3" (7.6 cm)

0"

     (0 cm)

23

⁷⁄₈

"

(60.64 cm)

24 in.

(155 cm

2

)

48 in.

(310 cm

2

)

   1"

(2.5 cm)

27¼"

 (69.22 cm)

5½"

(14 cm)

Summary of Contents for 8542748

Page 1: ...red if you don t immediately You can be killed or seriously injured if you don t follow All safety messages will tell you what the potential hazard is tell you how to reduce the chance of injury and tell you what can happen if the instructions are not followed Your safety and the safety of others are very important We have provided many important safety messages in this manual and on your applianc...

Page 2: ...ens to 1 2 5 cm or 14 mm open end wrench for adjusting dryer feet Level nut driver or socket wrench Wood block for leveling Ruler or measuring tape Wire stripper direct wire installations Knife Vent clamps Caulking gun and compound for installing new exhaust vent Pliers Scissors Tin snips for new vent installations A Water inlet hoses 2 B Inlet hose flat washers 4 C Rear leveling legs 2 D Front le...

Page 3: ...arance behind the dryer for the exhaust vent with elbow See Venting Requirements Minimum installation spacing for recessed area or closet installation The following dimensions shown are for the minimum spacings allowed Additional spacing should be considered for ease of installation and servicing Additional clearances might be required for wall door and floor moldings Additional spacing of 1 2 5 c...

Page 4: ...circuit fused on both sides of the line A time delay fuse or circuit breaker is recommended Connect to an individual branch circuit Do not have a fuse in the neutral or grounding circuit Do not use an extension cord If codes permit and a separate ground wire is used it is recommended that a qualified electrician determine that the ground path is adequate Electrical Connection To properly install y...

Page 5: ...opper wire do not use aluminum At least 5 ft 1 52 m long For a grounded cord connected washer dryer This washer dryer must be grounded In the event of malfunction or breakdown grounding will reduce the risk of electric shock by providing a path of least resistance for electric current This washer dryer uses a cord having an equipment grounding conductor and a grounding plug The plug must be plugge...

Page 6: ...G Fire Hazard Use a new UL listed 30 amp power supply cord Use a UL listed strain relief Disconnect power before making electrical connections Connect neutral wire white or center wire to center terminal silver Ground wire green or bare wire must be connected to green ground connector Connect remaining 2 supply wires to remaining 2 terminals gold Securely tighten all electrical connections Failure...

Page 7: ... slot of dryer rear panel Secure cover with hold down screw If your home has And you will be connecting to Go to Section 4 wire receptacle NEMA Type 14 30R A UL listed 120 240 volt minimum 30 amp dryer power supply cord 4 wire connection Power supply cord 4 wire direct A fused disconnect or circuit breaker box 4 wire connection Direct Wire 3 wire receptacle NEMA type 10 30R A UL listed 120 240 vol...

Page 8: ...he internal to the external ground location Connect ground wire green or bare of power supply cable to external ground conductor screw Tighten screw 4 Place the hooked end of the neutral wire white or center wire of power supply cable under the center screw of terminal block hook facing right Squeeze hooked end together Tighten screw 5 Place the hooked ends of the other power supply cable wires un...

Page 9: ...ering Shape ends of wires into a hook shape When connecting to the terminal block place the hooked end of the wire under the screw of the terminal block hook facing right squeeze hooked end together and tighten screw 1 Loosen or remove center terminal block screw 2 Place the hooked end of the neutral wire white or center wire of power supply cable under the center screw of terminal block hook faci...

Page 10: ...gas vent chimney wall ceiling or a concealed space of a building Do not use an exhaust hood with a magnetic latch Do not install flexible metal vent in enclosed walls ceilings or floors Use clamps to seal all joints Exhaust vent must not be connected or secured with screws or other fastening devices which extend into the interior of the duct Do not use duct tape IMPORTANT Observe all governing cod...

Page 11: ...ectDrainHose Proper connection of the drain hose protects your floors from damage due to water leakage To prevent the drain hose from coming off or leaking it must be installed according to the following instructions IMPORTANT To ensure proper installation this procedure must be followed exactly 1 Check the drain hose to see whether it is the proper length 2 Wet the inside of the straight end of t...

Page 12: ...sher 6 Attach the hose with the blue coupling to the cold water top inlet valve Screw on coupling by hand until it is seated on the washer Using pliers tighten the couplings with an additional two thirds turn NOTE Do not overtighten Damage to the valves can result 7 Attach the hose with the red coupling to the hot water bottom inlet valve Screw on coupling by hand until it is seated on the washer ...

Page 13: ...77784 biscuit Follow the instructions in the kit to install Kits are available from the dealer from whom you purchased your washer dryer Alternate installations for close clearances Venting systems come in many varieties Select the type best for your installation Three close clearance installations are shown Refer to the manufacturer s instructions provided with the vent system NOTE The following ...

Page 14: ...ORTANT Do not use vent runs longer than those specified in the Vent Length Chart The following chart helps you determine your maximum vent length based on the number of 90 turns or elbows you will need and the type of vent rigid metal or flexible metal and hood that you will use Vent Length Chart NOTE Side exhaust adds a 90 turn inside the washer dryer To determine maximum exhaust length add one 9...

Page 15: ...and front leveling feet are tight See Level Washer Dryer 6 Plug into a grounded outlet Turn on power 7 Check to be sure the water faucets are on 8 Check for leaks around faucets and inlet hoses 9 Remove the blue protective film on the console and any tape remaining on the washer dryer 10 Read your Washer Dryer User Instructions 11 Wipe the dryer drum interior thoroughly with a damp cloth to remove...

Page 16: ...8542748A 2004 All rights reserved Benton Harbor Michigan 49022 TM DURASAFE is a trademark of Whirlpool U S A 10 04 Printed in U S A ...