Secure Drain Hose

1. Move the washer/dryer to its final location and remove any 

cardboard used to move the washer/dryer.

2. Locate the plastic strap included in the parts package.

Beaded tie strap

3. Wrap the drain hose to the laundry tub leg or standpipe with 

the plastic strap (A or B below) and secure.

If the water faucets and the drain standpipe are recessed, put 
the hooked end of the drain hose in the standpipe. Tightly 
wrap the plastic strap around the water inlet hoses and the 
drain hose (C above).

Plan Vent System

Typical exhaust installations 

Typical installations vent the dryer from rear of the washer/dryer. 
Other installations are possible.

Optional exhaust installations 

This washer/dryer can be converted to exhaust out the right or left 
side. To convert the washer/dryer, use Side Exhaust Kit 
Part Number 279823. If your washer/dryer was previously 
exhausted from the right or left side, it can be converted to rear 
exhaust by using standard offset connections. To cover the hole in 
the side, one of the following plugs can be added:
692790 (white)
3977784 (biscuit)

Follow the instructions in the kit to install. Kits are available from 
the dealer from whom you purchased your washer/dryer. 

Alternate installations for close clearances

Venting systems come in many varieties. Select the type best for 
your installation. Three close-clearance installations are shown. 
Refer to the manufacturer’s instructions provided with the vent 
system.

NOTE: The following kits for close clearance alternate installations 
are available for purchase. Please reference the “Assistance or 
Service” section of your “Washer/Dryer User Instructions.”

Over the top Installation: 

Part Number 4396028

Periscope Installation (For use with dryer vent to wall vent 
mismatch):

Part Number 4396037 - 0" (0 cm) to 18" (45.72 cm) mismatch

Part Number 4396011 - 18" (45.72 cm) to 29" (73.66 cm) 
mismatch

Part Number 4396014 - 29" (73.66 cm) to 50" (127 cm) 
mismatch

A. Dryer
B. Rigid metal or 

flexible metal vent

C. Clamps
D. Wall

E. Elbow

F. Clamps

G. Elbow
H. Exhaust hood

C

B

A

A

B

C

D

E

F

G

H

A. Standard rear offset exhaust installation
B. Rear exhaust for offset close clearance connection

C. Left or right side exhaust installation

 A. Loop system with standard elbows

B. Loop system with one offset & one standard elbow

C. Vent system with one periscope (2" [5 cm] clearance)

A

B

C

A

B

C

Summary of Contents for 8542748

Page 1: ...red if you don t immediately You can be killed or seriously injured if you don t follow All safety messages will tell you what the potential hazard is tell you how to reduce the chance of injury and tell you what can happen if the instructions are not followed Your safety and the safety of others are very important We have provided many important safety messages in this manual and on your applianc...

Page 2: ...ens to 1 2 5 cm or 14 mm open end wrench for adjusting dryer feet Level nut driver or socket wrench Wood block for leveling Ruler or measuring tape Wire stripper direct wire installations Knife Vent clamps Caulking gun and compound for installing new exhaust vent Pliers Scissors Tin snips for new vent installations A Water inlet hoses 2 B Inlet hose flat washers 4 C Rear leveling legs 2 D Front le...

Page 3: ...arance behind the dryer for the exhaust vent with elbow See Venting Requirements Minimum installation spacing for recessed area or closet installation The following dimensions shown are for the minimum spacings allowed Additional spacing should be considered for ease of installation and servicing Additional clearances might be required for wall door and floor moldings Additional spacing of 1 2 5 c...

Page 4: ...circuit fused on both sides of the line A time delay fuse or circuit breaker is recommended Connect to an individual branch circuit Do not have a fuse in the neutral or grounding circuit Do not use an extension cord If codes permit and a separate ground wire is used it is recommended that a qualified electrician determine that the ground path is adequate Electrical Connection To properly install y...

Page 5: ...opper wire do not use aluminum At least 5 ft 1 52 m long For a grounded cord connected washer dryer This washer dryer must be grounded In the event of malfunction or breakdown grounding will reduce the risk of electric shock by providing a path of least resistance for electric current This washer dryer uses a cord having an equipment grounding conductor and a grounding plug The plug must be plugge...

Page 6: ...G Fire Hazard Use a new UL listed 30 amp power supply cord Use a UL listed strain relief Disconnect power before making electrical connections Connect neutral wire white or center wire to center terminal silver Ground wire green or bare wire must be connected to green ground connector Connect remaining 2 supply wires to remaining 2 terminals gold Securely tighten all electrical connections Failure...

Page 7: ... slot of dryer rear panel Secure cover with hold down screw If your home has And you will be connecting to Go to Section 4 wire receptacle NEMA Type 14 30R A UL listed 120 240 volt minimum 30 amp dryer power supply cord 4 wire connection Power supply cord 4 wire direct A fused disconnect or circuit breaker box 4 wire connection Direct Wire 3 wire receptacle NEMA type 10 30R A UL listed 120 240 vol...

Page 8: ...he internal to the external ground location Connect ground wire green or bare of power supply cable to external ground conductor screw Tighten screw 4 Place the hooked end of the neutral wire white or center wire of power supply cable under the center screw of terminal block hook facing right Squeeze hooked end together Tighten screw 5 Place the hooked ends of the other power supply cable wires un...

Page 9: ...ering Shape ends of wires into a hook shape When connecting to the terminal block place the hooked end of the wire under the screw of the terminal block hook facing right squeeze hooked end together and tighten screw 1 Loosen or remove center terminal block screw 2 Place the hooked end of the neutral wire white or center wire of power supply cable under the center screw of terminal block hook faci...

Page 10: ...gas vent chimney wall ceiling or a concealed space of a building Do not use an exhaust hood with a magnetic latch Do not install flexible metal vent in enclosed walls ceilings or floors Use clamps to seal all joints Exhaust vent must not be connected or secured with screws or other fastening devices which extend into the interior of the duct Do not use duct tape IMPORTANT Observe all governing cod...

Page 11: ...ectDrainHose Proper connection of the drain hose protects your floors from damage due to water leakage To prevent the drain hose from coming off or leaking it must be installed according to the following instructions IMPORTANT To ensure proper installation this procedure must be followed exactly 1 Check the drain hose to see whether it is the proper length 2 Wet the inside of the straight end of t...

Page 12: ...sher 6 Attach the hose with the blue coupling to the cold water top inlet valve Screw on coupling by hand until it is seated on the washer Using pliers tighten the couplings with an additional two thirds turn NOTE Do not overtighten Damage to the valves can result 7 Attach the hose with the red coupling to the hot water bottom inlet valve Screw on coupling by hand until it is seated on the washer ...

Page 13: ...77784 biscuit Follow the instructions in the kit to install Kits are available from the dealer from whom you purchased your washer dryer Alternate installations for close clearances Venting systems come in many varieties Select the type best for your installation Three close clearance installations are shown Refer to the manufacturer s instructions provided with the vent system NOTE The following ...

Page 14: ...ORTANT Do not use vent runs longer than those specified in the Vent Length Chart The following chart helps you determine your maximum vent length based on the number of 90 turns or elbows you will need and the type of vent rigid metal or flexible metal and hood that you will use Vent Length Chart NOTE Side exhaust adds a 90 turn inside the washer dryer To determine maximum exhaust length add one 9...

Page 15: ...and front leveling feet are tight See Level Washer Dryer 6 Plug into a grounded outlet Turn on power 7 Check to be sure the water faucets are on 8 Check for leaks around faucets and inlet hoses 9 Remove the blue protective film on the console and any tape remaining on the washer dryer 10 Read your Washer Dryer User Instructions 11 Wipe the dryer drum interior thoroughly with a damp cloth to remove...

Page 16: ...8542748A 2004 All rights reserved Benton Harbor Michigan 49022 TM DURASAFE is a trademark of Whirlpool U S A 10 04 Printed in U S A ...

Reviews: