WHIRLPOOL CONSUMER SERVICES
Model 6ADP2956 IXM
Page 5 of 19
TECHNICAL DATA (Cont.)
Heating
Voltage
230 - 240 V
Power consumption
2.22
kW
Resistance
25
•
Heating rate
2
º
C/min
Temperature on surface
~
115
º
C
Double safety element
85
º
C
cut-out, self resetting
Water Valves
Double Valve at Inlet Hose
Voltage
230 - 240
V
Frequency
50 - 60
Hz
Resistance
2.0
k
•
Zone Washing Valve
Voltage
230 - 240
V
Frequency
50 - 60
Hz
Resistance
4.0
k
•
Dispenser Coil
Voltage
230 - 240
V
Frequency
50 - 60
Hz
Resistance
1.5
k
•
Reed Contact
Flow meter
Rinse aid control
NTC
20
º
C
58.1
k
•
25
47.1
k
•
30
º
C
38.2
k
•
40
º
C
25.4
k
•
50
º
C
17.2
k
•
60
º
C
11.8
k
•
70
º
C
8.3
k
•
80
º
C
6
k
•
85
º
C
4
k
•
Water Quantities and Levels
Measuring Water Level
Remove the coarse sieve, place end of a ruler
in the bottom of the sump to measure the depth
of the water.
Water Quantities (Normal Programme (6a))
Back Rinse (x3)
1.0 litre
68mm
Prewash
4.8 litres
122mm
Prewash/Zone wash 4.0 litres
120mm
Main Wash
4.5 litres
121mm
Main wash/
Zone washing
3.5 litres
117mm
Intermediate rinse1 4.0 litres
120mm
Intermediate rinse1/
Zone washing
3.5 litres
117mm
Intermediate rinse2 4.0 litres
120mm
Intermediate rinse2/
Zone washing
3.5 litres
117mm
Clear rinse
4.0 litres
120mm
Clear rinse/
Zone washing
3.5 litres
117mm
Safety / Overflow
8.5 litres
141mm
Detergent max.
Pre-wash
10
cm
3
Main-wash
45
cm
3
Rinse aid
125
cm
3
6 Dosage steps
1 - 6
cm
3
Operating Speeds
Spray pump motor
2800
rpm
Drain pump motor
3000
rpm
Spray arm, lower
20 - 40
rpm
Spray arm, middle
25 - 35
rpm
Spray arm, upper
45 - 65
rpm
Drying fan
2500
rpm