WHIRLPOOL CONSUMER SERVICES
Model 6ADP2956 IXM
Page 19 of 19
CONTROL BOARD TEST POINTS
A pair of long, wire claw type probes are required to access the test points.
Checking voltages at the test points will determine the correct operation of the function push
buttons and the rotary switch.
Before
attaching test probes to the control board test points which are accessed via the control
board service window, disconnect the dishwasher from the supply. Short circuiting of any of the
electronic components will cause the control board to fail.
Test Points : T0 = Common
T2 = Analogue voltage
T1 = Analogue voltage
T3 = Digital signal
T0 T3 T2
T1
Control Board
A voltmeter with a high input impedance is required to measure the control board voltages.
The degree of agreement between the measured voltage and the nominated voltage will be
dependent on the accuracy of the voltmeter.
Test Point T0 to T1
Communication between control board and display board
Operated Push Button Voltage (V dc)
All off
-5.24
ZW (1 or both LED's)
-3.43
Delay
-2.88
ZW and Delay
-2.88
Test Point T0 to T2
Communication between control board and user board
Rotary Switch Voltage (V dc)
O
0.00
Cycle 1
-1.32
Cycle 2
-1.75
Cycle 3
-2.20
Cycle 4
-2.90
Cycle 5
-3.36
Cycle 6
-3.80
Test Point T0 to T3
Communication between control board and display board
Start button out (LED off)
-5.24 V dc
Start button in (LED on)
-3.87 V dc
Service Window