WHIRLPOOL CONSUMER SERVICES
Model 6ADP2956 IXM
Page 18 of 19
ACTIVE TEST PROGRAMME
Start the active test procedure by first running the passive test then press the start button for
less than three seconds.
Notes :
When the machine detects a fault during
normal operation the start light will begin to
flash and the cycle may or may not stop.
When the control knob is turned to zero the
fault is stored
(except Fault Code F6)
and
the fault code will be displayed when the
passive test is run. For the diagnostics to
locate fault code F6, the active test
procedure
MUST
be followed.
The active test programme runs for
approximately 21 minutes or, if the heat cycle
is bypassed the test runs for approximately 4
minutes.
The active test programme runs to the point
of failure then stops. If there is no failure the
test programmes runs to the end.
To exit the test programme, press the
START
button for more than three seconds.
An empty rinse aid container will not
cause the test programme to stop, only
illuminate the red LED.
Zone Wash Valve "on" results in no water
spraying from the centre spray arm.
Zone Wash Valve "off" results in water
spraying from the centre spray arm.
Operation
Function
Start
Backrinsing
(only after
second run of
test
programme)
Fill and pump at the
same time
(flushing) three
times, 15 seconds
each time
Washing
Fills, spray pump
starts & continues
to fill, zone wash
valve (ZW) on. Fill
stops, pump & ZW
off for 3 sec.
Detergent
dispenser on for
3 sec, pump
restarts, 5 sec
delay then heating
element on
Water heated to
65
°
C
30 sec delay
Pumpout
Filling
Pumpout
End
END light on