3-8
n
Whirlpool Compact Heat Pump Dryer
COMPONENT TESTING
TEST #3 Motor Circuit (M)
This test will check the wiring to the motor and the motor
itself. The following items are part of this motor system:
Part of Motor System
Heat Pump Dryer
Drum belt
ü
Door switch
ü
Harness/connection
ü
Drive motor
ü
Appliance Control Unit (ACU)
ü
NOTE:
Verify motor movement in steps
S02
and
S03
of Service
Test Cycle (page 4). If no motor movement, proceed with the
following procedure.
1. Unplug dryer or disconnect power.
2. Remove top panel, left side panel, and console to access
the machine electronics.
3. Door Switch problems can be uncovered by following
procedure under TEST #7: Door Switch, page 20; however,
the door switch is inside the ACU and no port is available.
For Service Technician Use Only
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Failure to do so can result in death or
electrical shock.
Replace all parts and panels before operating.
MOTOR STRIP CIRCUIT
4. Check the wiring and components:
a. Check for loose, worn, or damaged drum belt—repair
as necessary.
b. Verify that the spring and support structure is in
position and in good condition.
c. Make sure there is no obstruction to drum movement.
Check J12 and J4 connections on ACU to motor.
d. Check continuity. If there is no continuity, replace the
wiring harness. If there is continuity, replace the drive
motor.
5. If the preceding steps do not correct the problem, replace
the ACU.
6. Reassemble all parts and panels.
7. Plug in dryer or reconnect power.
8. Perform the Service Test Cycle on pages 3 and 4 to verify
repair.
Motor Assembly
L1
RELAY K6
MOTOR
J4-1
BK
R
J13-1
BK
GY
GY
L2
GY
BU
ACU
RELAY K5
J13-2
J4-2
ACU
R
RFI-2
RFI-1
J12-2
J12-3
J12-4
1
2
3
2
1
MOTOR CONTROL
M
MOTOR
BU
VCC
IN/OUT
GND
L1
L2
Figure 1 - Motor Strip Circuit
Motor
Assembly
Idler
Pulley
Drum
Belt
Blower
Screw
Blower
Wheel
Belt Tension
Spring
Motor
Bracket
Motor
Bracket