Select Constant vacuum
Selecting constant vacuum will cause the vacuum pump
to run continuously during the vacuum cycle of a program.
1. Press the
Special Functions
button.
2. Turn the
Select Knob
until the display reads
CONSTANT VC PUMP.
3. Press the
Next
button.
4. Turn the
Select Knob
to display YES or NO. A
selection of YES will cause the vacuum pump to run
continuously during the vacuum cycle of a program.
A selection of NO will allow the vacuum pump to
turn off and on to maintain the set vacuum level.
If intermittant vacuum is selected but the vacuum
pump runs continuously during the program cycle,
the vacuum level is set too high. The actual level is
within 3% of the selected level, but the pump can-
not reach the full selected level. This can be cor-
rected by reducing the vacuum level. See page 11
for more detail.
5. Press the
Next
button.
Special Cool Position
This feature is only available when running a
Special Porcelain Program. For further information,
see page 20.
This feature allows the user to select the height that the table
lowers to for cooling during the special cool time. This feature
is used only when running a “Spec” special porcelain program.
The default number is 50. The higher the number, the further
the table will drop. See Chapter Three — Special Firing Cycle
Program for more detail.
To set the height of the table follow these directions:
1. Press the
Special Functions
button.
2. Turn the
Select Knob
until the display reads
SP COOL POSITION. Press the
Next
button.
3. SPECIAL COOL TIME = 50 is now displayed.
Turn the
Select Knob
to select a new position
value. To determine the value desired, turn the
Select Knob
until the number displayed will
not go any higher. This highest number represents
the table fully down position. You can then divide
by 2 for
1
/
2
-way down, 3 for
1
/
3
-way down, 4 for
1
/
4
-way down, at a time.
4. Press the
Next
button.
Select Upper or Lower Case Letters
This feature allows you to select whether the display
reads in all capital letters or lower case and capital.
Selecting YES will cause the furnace to display in all
capital letters. Selecting NO will cause the furnace to
display lower and uppercase lettering.
1. Press
Special Functions.
2. Turn the
Select Knob
until the display reads
CAPITAL LETTERS?
3. Press the
Next
button and turn the
Select Knob
to display YES or to display NO.
Selecting YES will cause only capital letters to be
displayed, selecting NO will allow both capitals
and lower case letters to display.
4. Press the N
ext
button.