background image

Page 2

Mounting
Flange

# 4

S h e e t

m e t a l

s c r e w

Lighthead

Gasket

MOUNTING
SURFACE

1.874"

WIRE
HOLE

O N E
INCH

MOUNTING HOLES

3 AMP

F u s e

Connect to other SYNC capable

product or cap off wire.

GREEN

BLACK

RED

WHITE

BATTERY

Normally Open
Momentary Switch

S P S T
Switch

F

SignalAlert™ 75
SignalAlert™ 75
CometFlash® 75
CometFlash® 75
DoubleFlash 75
DoubleFlash 75

PH1
PH2
PH1
PH2
PH1
PH2

PingPong™

SingleFlash 90
SingleFlash 120
SingleFlash 300
DoubleFlash 150
ComAlert™ 150

Non-SYNC Patterns

PH2

14.

15.
16.
17.
18.
19.

Non-SYNC Patterns

Flash Patterns / SYNC
1.
2.
3.
4.
5.
6.

.

8.
9.
10.
11.
12.
13.

7

20.
21.
22.
23.
24.

SingleFlash 75
SingleFlash 75
ComAlert™
ComAlert™
LongBurst™
LongBurst™
PingPong ™

PH1
PH2
PH1
PH2
PH1
PH2
PH1

ActionFlash™ 1
ActionFlash™ 2
M o d u F l a s h ™
A c t i o n S c a n ™
Steady

CAUTION! DO NOT LOOK DIRECTLY AT

THESE LEDS WHILE THEY ARE ON.

MOMENTARY BLINDNESS AND/OR EYE

DAMAGE COULD RESULT!

IMPORTANT WARNING!

WARNING: All customer supplied wires that connect to the positive
terminal of the battery must be sized to supply at least 125% of the
maximum operating  current and  FUSED at  the battery to carry  that
load. DO NOT USE CIRCUIT BREAKERS WITH THIS PRODUCT!

Permanent  mounting  of  this  product  will  require  drilling.  It  is
absolutely necessary to make sure that no other vehicle components
could  be  damaged  by  this  process.  Check  both  sides  of  the
mounting  surface  before  starting.  If  damage  is  likely,  select  a
different mounting location.

IMPORTANT!  It is the responsibility of the installation technician to
make sure that the installation and operation of this product will not
interfere  with  or  compromise  the  operation  or  efficiency  of  any
vehicle equipment!

IMPORTANT! Before returning the vehicle to active service, visually
confirm  the  proper  operation  of  this  product,  as  well  as  all  vehicle
components/equipment.

Installation:

1.

Place  the  flange  onto  the  mounting  surface  in  its  exact  mounting
position  and  mark  off  the  location  of  the  2  mounting  holes  and  the
center wire hole. 

2.

Drill two mounting holes for the two supplied #4 sheet metal screws
(Use a #47 drill bit). Also drill a 1” wire hole in the center of the two
mounting holes.

3.

Insert the lighthead cable and driver module into the wire hole, add
the gasket and secure the light with the sheet metal screws supplied.

4.

Extend  the  red  and  black  wires  to  your  power  source  and  wire  as
shown in the wiring diagram

Wiring & Operation:

This LED lighthead is powered & controlled by a 4-wire cable. All
switches, fuses and fuse blocks are customer supplied.

RED: 

Positive

 -

 Extend RED wire to +12V DC. (Fuse @ 3 amps).

BLACK:

 

Ground

 -

 Extend BLACK wire to negative terminal of battery.

GREEN:

 

SYNC

 -

 Connect GREEN wire to other SYNC capable lights to

synchronize output. Cap this wire off if it is not used.

WHITE:

 

Scan-Lock™

  -

  Extend  WHITE  wire  to  customer

supplied momentary switch (Fuse @ 1 amp).

WARNING: DO NOT ATTEMPT TO USE THIS LIGHTHEAD
WITHOUT THE LED DRIVER MODULE CONNECTED.

Scan-Lock™

In order to program flash patterns, the lighthead must be on. With
the lighthead activated:

TO CHANGE PATTERNS:

 To advance to the next pattern apply +12VDC

to the WHITE wire for less than 1 second and release. To cycle back to the
previous pattern apply +12VDC to the WHITE wire for more than 1 second
and release.

TO  CHANGE  THE  DEFAULT  PATTERN:

  When  the  desired  pattern  is

displayed, allow it to run for more than 5 seconds. The lighthead will now
display this pattern when initially activated.

TO  RESTORE  THE  FACTORY  DEFAULT  PATTERN:

  With  the  light

turned  off,  apply  power  to  the  WHITE  wire.  With  power  applied  to  the
WHITE wire, turn the light on. Allow the unit to run for 3 seconds before
removing power from the WHITE wire.

A normally open momentary switch should be used to control Scan-Lock
operation.

SYNC:

To SYNC  two or more lightheads, configure  all lightheads to  display  the
same  Phase  1  pattern.  Turn  the
lightheads  off  and  connect  the  GREY
wires  coming  from  the  lightheads
together.  When  the  lightheads  are
activated,  the  patterns  displayed  will  be
synchronized.  To  configure  specific
lightheads to alternate their patterns with
other lightheads, advance the pattern of
either lighthead to Phase 2 of the current
pattern.

Phase Operation

Phase  1  (PH1)  flashes  simultaneously
with PH1
Phase  2  (PH2)  flashes  simultaneously
with PH2
PH1 alternates with PH2

Reviews: