background image

Page 2

TO LIGHTHEAD

2

1

2

3

GREEN

BROWN

ORANGE

TO POWER SUPPLY

STROBE

GROUND

ANODE

TRIGGER

1

2

3

1

2
3

WHITE

BLACK

RED

1

2

3

WHITE

BLACK

RED

TO LIGHTHEAD

1

2

3

WHITE

BLACK

RED

3

2

1

1

2

3

1

3

3

4

4

4
3
2
1
-

39-0404313-04
39-0403013-04
26-0610153-00
46-0742592-00

2
2
2
1

-

PART NUMBER

ITEM QTY.

DESCRIPTION

3 POS. SOCKET HSG. AMP 1-480303-0
3 POS. PIN HSG. AMP 1-480305-0
PVC TUBE (20“)
CABLE, 6 CONDUCTOR/18 AWG (8.5’)

“Y” HARNESS - MOTORCYCLE PAR-36

46-0960536-00

3 POS. PIN HSG

POS.1 - RED

POS.2 - BLACK

POS.3 - WHITE

3 POS. PIN HSG

POS.1 - ORANGE

POS.2 - BROWN

POS.3 - GREEN

The PAR-36 Motorcycle “Y” Harness can be 
used for any motorcycle application to connect 
a strobe power supply to your strobe light 
heads. 

WARNING: The Strobe Light Power Supply 
is a high voltage device. Do not touch or 
remove tube assembly in strobe light head 
assemblies while in operation. Wait 10 min-
utes after disconnecting the unit from its 
power source before starting work or trou-
bleshooting power supply or system.

Installation . . .

Follow the diagram to the left to connect the 
wires to their pin and socket housings. Then  
connect your power supply to the strobe lights 
by connecting the amp socket and pin hous-
ings as shown. Do not turn the power supply 
on before completeing all connections.