Whelen Engineering Company 295HFSA5 Installation Manual Download Page 6

Page 6

VEHICLE

HORN

+12V

HORN

RELAY

CUT
WIRE

TO HORN

BUTTON

SIREN INPUT CONNECTOR

3

AMP

FUSE

CUST

OMER

SUPPLIED

WIRING DIAGRAM

T

O

TWO

W

A

Y

-

RADIO

SPEAKER

2 9 5 H F S _ 5

P1

P4

SWITCH

8

OUTPUT

BACKLGHTING

12V BATTERY

3

4

5

9 8 7 6

2 1

9

4

1 5 2

6 3 7 8 12 10 11

BLUE

VIOLET

RED

RED

BLACK

BLACK

BLUE

BROWN

ORANGE

YELLOW

GREY

WHITE

BLACK

RED

BLUE

BLUE

YELLOW

ORANGE

BROWN

3

4

1

2

SPKR.

#1

11 OHM

SPKR.

#2

11 OHM

SIREN

S

HUTDOWN

20

AMP

FUSE

CUST

OMER

SUPPLIED

WHT/BLK

-

SW#4

OUTPUT

ORN

-

SW#7

OUTPUT

YEL

-

SW#6

OUTPUT

WHT

-

SW#5

OUTPUT

GR

Y

-

SLIDE

SW#2

OUTPUT

BLU

-

SLIDE

SW#3

OUTPUT

VIO

-

HI/LOW

CONTROL

(EDGE

ONL

Y)

GRN

-

SLIDE

SW#1

OUTPUT

BRN

-

see

note

2

OUTPUTS

P2

WHITE

/

GREEN

RED

-

see

note

1

BLACK

/

WHITE

WHITE

/

RED

REMOTE

ACTIV

A

TION

Note 1 - This RED wire provides power to the push-buttons.

Fuse @ 3 amps and connect to sw12VDC.

Note 2 - This BROWN wire provides power to the slide switch.

Fuse @ 3 amps and connect to +12VDC.

RECOMENDED SIZE for CUSTOMER SUPPLIED WIRES:

Switch Power

18 AWG..............................................................13 FT. MAX
16 AWG..............................................................21 FT. MAX

Siren Power & Ground

12 AWG..............................................................18 FT. MAX
10 AWG..............................................................30 FT. MAX

DIAGNOSTIC INDICATORS

There are has two diagnostic indicators on the front panel which 
are used to indicate fault conditions with your siren system. The 
following table lists the type of fault and the indicators response. 
If the indicator is on steady while a tone is in use, this implies 
that there is no fault with the associated speaker output. 

Fault Condition and Diagnostic Indicator Response:

Under Voltage

 

Speaker LED #2 will be in a double flash 

mode (2 quick flashes followed by a longer pause) and the 
siren tones will not operate.

Over Voltage

 

Speaker LED #1 will be in a double flash 

mode (2 quick flashes followed by a longer pause) and the 
siren tones will not operate

.

Speaker #1 Short Circuit

 

Speaker LED # 1 will be in a sin-

gle flash mode (the LED will be on and off an equal

 

amount 

of time) and the siren tones will not operate.

Speaker #2 Short Circuit

 

Speaker LED #2 will be in a sin-

gle flash mode (the LED will be on and off an equal

 

amount 

of time) and the siren tones will not operate.

Speaker #1 (Not Connected)

 

Speaker LED #1 will be off, 

all tones will continue to operate.

Speaker #2 

(Not Connected)

 

Speaker LED #2 will be off, 

all tones will continue to operate.

Rotary Switch Operations:

RAD (Radio Repeat) -

  When  the  rotary  knob  is  in  the  RAD

position,  any  signal  that  is  received  by  the  vehicle’s  two-way
radio  will  be  simultaneously  broadcast  over  the  vehicle’s
loudspeaker  (unit  must  be  connected  to  the  two-way  radio  as
outlined in this manual). 

With the Rotary Switch in this Position:

Pressing the MAN switch will result in SI TEST® (see SI TEST 
section)

Pressing the HORN switch will result in the AIRHORN tone until 
the HORN switch is released.

Activating the HORN RING input results in the AIRHORN tone 
until the HORN RING input is released.

Activating the SIREN SHUTDOWN input has no effect.

Activating the AUX ENABLE input has no effect.

SPECIFICATIONS

INPUT VOLTAGE

. . . . . . . . . . . . . . . . . . . . .  12.5 VDC ±20%

INPUT CURRENT 

@15 VDC @ 5.5 OHMS

 . 16 AMPS MAX.

INPUT FUSE

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 AMPS

SPEAKER IMPEDANCE

. . . . . . . . . . . . . . . .5.5 OHMS MIN.

OPERATING TEMPERATURE

 . . . . . . . . -30° C. TO +60° C.

STORAGE TEMPERATURE

 . . . . . . . . . . -40° C. TO +70° C.

HUMIDITY

 . . . . . . . . . . . . . . . . .  99% (NON CONDENSING)

OUTPUT VOLTAGE

 

@ 15 VDC @ 11 OHMS 

32 V RMS MAX.

OUTPUT POWER

@ 15 VDC @ 11 OHMS

 105 WATTS MAX.

OUTPUT POWER

@ 15 VDC @ 5.5 OHMS 

185 WATTS MAX.

Summary of Contents for 295HFSA5

Page 1: ...tion around live electrical connections Grounding or shorting of electrical connections can cause high current arcing which can cause personal injury and or vehicle damage including fire Many electronic devices used in emergency vehicles can create or be affected by electromagnetic interference Therefore after installation of any electronic device it is necessary to test all electronic equipment s...

Page 2: ...UIT IS A VIOLATION OF THE FEDERAL MOTOR VEHICLE SAFETY STANDARD FOR THE THIRD BRAKE LIGHT AS WELL AS REAR BRAKE LIGHTS FUNCTIONS THAT BLACK OUT THE REAR BRAKE LIGHTS SOMETIMES CALLED BRAKE LIGHT CUT OUT MAY INTERFERE WITH THE BRAKE SHIFT LOCK MECHANISM AND CAUSE THE VEHICLE TO MOVE UNEXPECTEDLY AND DANGEROUSLY DISCONNECTING THE BRAKE LIGHTS IN ANY WAY IS AT YOUR OWN RISK AND IS NOT RECOMMENDED BY ...

Page 3: ...ER 2 Slide Switch Control Wires Green Grey Blue NOTE The push button and slide switch control wires are designed to activate relays with a coil rating nogreater than 250 ma Do not connect them to any circuit rated higher 1 Route and connect the GREEN wire to the desired lightbar function control wire s 2 Route and connect the GREY wire to the desired lightbar function control wire s 3 Route and co...

Page 4: ...on position 1 uses dip switch bank 1 position 2 uses dip switch bank 2 and position 3 uses dip switch bank 3 Each dip switch bank is comprised of 8 switches each representing a corresponding output switch 1 for output 1 switch 2 for output 2 etc If for example switches 1 3 4 6 on dip switch bank 1 are in the ON position outputs 1 3 4 6 will be active when the slide switch is moved to position 1 Sl...

Page 5: ...er removed from the PCCS9NP Mode 1 default In this configuration the output is activated for as long as push button 9 is depressed Mode 2 In this configuration when push button 9 is pressed the output is activated for a period of 8 seconds Mode 3 In this configuration when push button 9 is pressed the output is activated When pressed again the output is deactivated Mode 4 In this configuration whe...

Page 6: ...owed by a longer pause and the siren tones will not operate Over Voltage Speaker LED 1 will be in a double flash mode 2 quick flashes followed by a longer pause and the siren tones will not operate Speaker 1 Short Circuit Speaker LED 1 will be in a sin gle flash mode the LED will be on and off an equal amount of time and the siren tones will not operate Speaker 2 Short Circuit Speaker LED 2 will b...

Page 7: ...LP and PIERCER tones down However the HORN and the HORN RING switch will activate an AIRHORN tone and the MAN switch will activate a momentary WAIL tone Activating the AUX ENABLE input or slide switch position 3 if selected will start the HF cycle WAIL Wail Tone When the rotary knob is in the WAIL position a steady rise and fall tone Wail is produced With the Rotary Switch in this Position Pressin...

Page 8: ...he screwdriver in the Radio Repeat adjustment port and turn in clockwise direction to increase the sound level MAN BUTTON The Manual button generates a variety of tones depending on what position the rotary knob is in For further explanation of this button s function refer to Rotary Switch Operations SI TEST DIAGNOSTIC INDICATORS SI TEST is a diagnostic feature that allows the operator to confirm ...