Configuring the Slide Switch Functions:

In the default dip switch setting, the P1 outputs are:

Slide Switch Positions:

Push-Buttons:

0 =

 

Terminals OFF

4 =

 

White / Black

1 =

 

Green

5 =

 

White

2 =

 

Green / Grey

6 =

 

Yellow

3 =

 

Green / Grey / Blue

7 =

 

Orange

8 =

 

Black / White

9

 =

 Violet

Changing Default Slide Switch Control: 

Configuring Slide Switch Control: 

The slide switch has four positions: 0 (off), 1, 2 & 3. When in position 0 (furthest to the left) the slide switch has not activated
any outputs. In position 1, 2 or 3 the slide switch can activate any combination of outputs 1 through 8. Each active slide
switch position uses a bank of dip switches to determine which outputs are to be active while the slide switch is in that
position; position 1 uses dip switch bank 1, position 2 uses dip switch bank 2, and position 3 uses dip switch bank 3.

Each dip switch bank is comprised of 8 switches, each representing a corresponding output (switch 1 for output 1, switch 2
for output 2, etc.). If, for example, switches 1, 3, 4 & 6 on dip switch bank 1 are in the ON position, outputs 1, 3, 4 & 6 will be
active when the slide switch is moved to position 1.

Slide switch configuration is as simple as deciding which outputs are to be active in a given position and then moving the
corresponding dip switch on the appropriate dip switch bank to the ON position.

1 - Slide Switch Output 1 (GRN)
2 - Slide Switch Output 2 (GRY)
3 - Slide Switch Output 3 (BLU)
4 - Switch 4 Output (WHT/BLK)
5 - Switch 5 Output (WHT)
6 - Switch 6 Output (YEL)
7 - Switch 7 Output (ORN)
8 - Switch 8 Output (BLK/WHT)

8

7

6

5

4

3

2

1

= OFF

= ON

Dip Switch

Bank 1

Dip Switch

Bank 4

Dip Switch

Bank 2

Dip Switch

Bank 3

Summary of Contents for 295HFSA5

Page 1: ...tion around live electrical connections Grounding or shorting of electrical connections can cause high current arcing which can cause personal injury and or vehicle damage including fire Many electronic devices used in emergency vehicles can create or be affected by electromagnetic interference Therefore after installation of any electronic device it is necessary to test all electronic equipment s...

Page 2: ...UIT IS A VIOLATION OF THE FEDERAL MOTOR VEHICLE SAFETY STANDARD FOR THE THIRD BRAKE LIGHT AS WELL AS REAR BRAKE LIGHTS FUNCTIONS THAT BLACK OUT THE REAR BRAKE LIGHTS SOMETIMES CALLED BRAKE LIGHT CUT OUT MAY INTERFERE WITH THE BRAKE SHIFT LOCK MECHANISM AND CAUSE THE VEHICLE TO MOVE UNEXPECTEDLY AND DANGEROUSLY DISCONNECTING THE BRAKE LIGHTS IN ANY WAY IS AT YOUR OWN RISK AND IS NOT RECOMMENDED BY ...

Page 3: ...ER 2 Slide Switch Control Wires Green Grey Blue NOTE The push button and slide switch control wires are designed to activate relays with a coil rating nogreater than 250 ma Do not connect them to any circuit rated higher 1 Route and connect the GREEN wire to the desired lightbar function control wire s 2 Route and connect the GREY wire to the desired lightbar function control wire s 3 Route and co...

Page 4: ...on position 1 uses dip switch bank 1 position 2 uses dip switch bank 2 and position 3 uses dip switch bank 3 Each dip switch bank is comprised of 8 switches each representing a corresponding output switch 1 for output 1 switch 2 for output 2 etc If for example switches 1 3 4 6 on dip switch bank 1 are in the ON position outputs 1 3 4 6 will be active when the slide switch is moved to position 1 Sl...

Page 5: ...er removed from the PCCS9NP Mode 1 default In this configuration the output is activated for as long as push button 9 is depressed Mode 2 In this configuration when push button 9 is pressed the output is activated for a period of 8 seconds Mode 3 In this configuration when push button 9 is pressed the output is activated When pressed again the output is deactivated Mode 4 In this configuration whe...

Page 6: ...owed by a longer pause and the siren tones will not operate Over Voltage Speaker LED 1 will be in a double flash mode 2 quick flashes followed by a longer pause and the siren tones will not operate Speaker 1 Short Circuit Speaker LED 1 will be in a sin gle flash mode the LED will be on and off an equal amount of time and the siren tones will not operate Speaker 2 Short Circuit Speaker LED 2 will b...

Page 7: ...LP and PIERCER tones down However the HORN and the HORN RING switch will activate an AIRHORN tone and the MAN switch will activate a momentary WAIL tone Activating the AUX ENABLE input or slide switch position 3 if selected will start the HF cycle WAIL Wail Tone When the rotary knob is in the WAIL position a steady rise and fall tone Wail is produced With the Rotary Switch in this Position Pressin...

Page 8: ...he screwdriver in the Radio Repeat adjustment port and turn in clockwise direction to increase the sound level MAN BUTTON The Manual button generates a variety of tones depending on what position the rotary knob is in For further explanation of this button s function refer to Rotary Switch Operations SI TEST DIAGNOSTIC INDICATORS SI TEST is a diagnostic feature that allows the operator to confirm ...

Reviews: