12 of 31
Figure 3. electrical Schematic, 230 Volt, 1Ph. 60 Hz
NOTE:
Optional voltage and phase type power units will come with their own wiring diagram.
IMPORTANT: WITH THE MAIN ELECTRICAL SUPPLY CONNECTED, PRESS THE
UP CONTROL BUTTON TO RAISE THE LIFT 10” (254mm). STOP,
THEN PRESS THE DOWN CONTROL BUTTON TO LOWER THE
LIFT. REPEAT THIS PROCEDURE THREE (3) TIMES TO RELIEVE
AIR FROM THE HYDRAULIC SYSTEM. CHECK FOR HYDRAULIC
LEAKS AT ALL CONNECTIONS.
6.5 MECHANICAL SAFETY INSTALLATION
1.
Locate the two (2) mechanical safety release rods and one (1) mechanical safety release
connecting rod.
2. Raise the lift by pressing the up button on the hand control.
3.
Turn off the power supply to the power pack.
4. Slide each mechanical safety release rod through the holes closest to the rear of each
baseframe.