background image

 
 
 
1.  Zone page or All-Call 
     page cannot be  
     accessed 

 

 
 
 
1.  Telephone system must have touchtone (DTMF)  
     dialing. 
 
2.  Check presence and polarity of -24VDC and  
     GND for both "A"  and "B" battery. 
 
3.  Check sidetone in handset.  If there is no side  
     tone, recheck "A" and "B" battery, at least  
     -20VDC required. 

 
 
 
2.  No background music. 

 

 
 
 
1.  Verify unit has released from last page. 
 
2.  Check program source, and adjust its volume 
     control, as desired. 
 
3.  Check presence of music audio input at "T" in 
     and "R" in and if necessary also at the music  
     source. 
 
4.  Check presence of music audio input at "T" out  
     and "R" out and if necessary also at speaker  
     amps. or paging amp. input. 
 

 
 
 
3.  No sound or low page 
     volume. 

 

 
 
 
1.  Check presence and level of audio input at Tip 
      Ring and if necessary also at the CO Port. 
 
2.  Check presence and level of audio at "T" out  
     and "R" out and if necessary also at speaker  
     amps. input. 

 
 
 
4.  The alert tone is 
     too high or too low. 

 

 
 
 
1.  Set the alert Tone Volume to the desired  
     level. 

 
 
 
5.  Talkback does not 
     function properly. 

 

 
 
 
1.  If ZC-3 and TBM-101 or TBH-104 use separate  
     power supplies, then check to insure there is a  
     common GND connection between ZC-3 and  
     TBM-101 or TBH-104. 
 
2.  TBM-101 or TBH-104 inhibit (INH) terminal  
     must be connected to the ZC-3's proper zone  
     inhibit (INH) terminal. 
 
3.  Refer  TBM-101 or TBH-104 installation  
     instructions. 

 
 
 
 

 
 
 
 
 
 
 
 
 

P81414 K 

Sheet 5 of 6 

Limited Warranty 

 
Wheelock products must be used within their published specifications and must be PROPERLY specified, applied, installed, operated, maintained and 
operationally tested in accordance with these instructions at the time of installation and at least twice a year or more often and in accordance with local, 
state and federal codes, regulations and laws.  Specification, application, installation, operation, maintenance and testing must be performed by qualified 

Summary of Contents for ZC-3

Page 1: ... is causing the malfunction If the equipment is determined to be malfunctioning its use shall be discontinued until the problem has been corrected APPLICATION INFORMATION WARNING ANY MATERIAL EXTRAPOLATED FROM THIS DOCUMENT OR FROM WHEELOCK MANUALS OR OTHER DOCUMENTS DESCRIBING THE PRODUCT FOR USE IN PROMOTIONAL OR ADVERTISING CLAIMS OR FOR ANY OTHER USE INCLUDING DESCRIPTION OF THE PRODUCT S APPL...

Page 2: ... Tone Frequency 700 Hz Alert Tone Duration 500 m sec Alert Tone Level 11 dBm Page Input Output Level T R 15 10 dBm Page Input Output Impedance T R 600 Ohms Music Input Output Level 15 10 dBm Music Input Output Impedance 600 Ohms Operating Temperature 0 55 C Operating Humidity TO 85 RH Zone Control Access PRESS CO LINE BUTTON OR TOUCH DIAL NUMBER ASSIGNED TO PAGE Page Zone 1 Dial 1 Page Zone 2 Dial...

Page 3: ... SIMPLIFIED SCHEMATIC AND CONNECTION DIAGRAM Connect only if Wheelock TBM 101 or TBH 104 Talkback Modules are used P81414 K Sheet 3 of 6 The ZC 3 can be connected to an audio page port only if the audio page port provides A A 600 OHM low power audio output B Transmission of DTMF touchtones C A dry contact closure that closes when the port is selected and opens when the paging telephone hangs up ...

Page 4: ...ccess the CO port to which ZC 3 has been connected To initiate a zone page dial 1 2 or 3 on the telephone s touchtone keypad to select zone 1 2 or 3 respectively To initiate an All Call page dial 0 on the telephone s touchtone keypad Sequential selections can be made between zones from zones to All Call or from All Call to zones by simply dialing the next zone or All Call Sequential selections can...

Page 5: ...t and R out and if necessary also at speaker amps input 4 The alert tone is too high or too low 1 Set the alert Tone Volume to the desired level 5 Talkback does not function properly 1 If ZC 3 and TBM 101 or TBH 104 use separate power supplies then check to insure there is a common GND connection between ZC 3 and TBM 101 or TBH 104 2 TBM 101 or TBH 104 inhibit INH terminal must be connected to the...

Page 6: ...MEET ANY OTHER STANDARD OF PERFORMANCE OR THAT THE FUNCTIONS OR PERFORMANCE OF THE SOFTWARE WILL MEET THE USER S REQUIREMENTS WHEELOCK SHALL NOT BE LIABLE FOR ANY DELAYS BREAKDOWNS INTERRUPTIONS LOSS DESTRUCTION ALTERATION OR OTHER PROBLEMS IN THE USE OF A PRODUCT ARISING OUT OF OR CAUSED BY THE SOFTWARE THE LIABILITY OF WHEELOCK ARISING OUT OF THE SUPPLYING OF A PRODUCT OR ITS USE WHETHER ON WARR...

Reviews: